4-3
Section
Installing Data Carriers
53
V600-A84 Holders can be used to adjust the distance between a Data Carrier
and a metal surface by piling up more than one Holder. The Holders will lock in
place if they are piled in alternating directions. Each Holder is 5 mm thick.
Install the Sensors and Data Carriers so that they are as parallel as possible to
each other. Communications will be possible even if they are not perfectly paral-
lel, but the transmission distance will be affected, as listed in the following tables.
V600-HS63/67 Sensor
Data Carrier
Metal
casing
(1) Reduction in Transmission Distance for Misalignment in V600-D23P71
Sensor
Data Carrier misalignment (
θ
)
0
10
20
30
40
V600-HS63
0%
1%
3%
6%
10%
V600-HS67
0%
0%
2%
4%
6%
(2) Reduction in Transmission Distance for Misalignment in V600-D23P72
Sensor
Data Carrier misalignment (
θ
)
0
10
20
30
40
V600-HS63
0%
3%
4%
5%
7%
V600-HS67
0%
0%
4%
6%
12%
Mounting Conditions: Sensor surface-mounted to a metal surface, Data Carrier
mounted to non-metallic surface.
Effect of Misalignment