4-3
Section
Trigger Inputs and Output Format
52
Switch the Scene (@MS Unit No. Scene No.) 1:N Connection
Switches the scene number to be displayed.
Send
<Footer>
<Scene No.>
<Unit No.>
Receive
Data is output from the V530-R150 without polling commands.
Correctly switched:
<Header >
<Unit No.>
OK
<Footer>
Incorrectly switched:
<Header >
<Unit No.>
ER
<Footer>
4-3-2
Communications Mode: Host Link
Command Table
Command Code
Function
10
One shot reading
11
Start continuous reading
12
Stop continuous reading
20
Switch to a specified scene number
21
Increase the displayed scene number by one
22
Decrease the current scene number by one
23
Read the scene number currently displayed
Error Code Table
Following error codes are output according to the cause of errors
when NG reading judgment is output. (FP = Finder Pattern)
Refer to
9-2 Error Codes and Remedies for details.