4-3
Section
Trigger Inputs and Output Format
51
Incorrect reading:
<Header >
<Unit No.>
<Error Code>
<FCS>
<Footer>
When Reading Accuracy is ON:
<Header >
<Unit No.>
<Reading Data>
<FCS> <Footer>
The judgment (reading accuracy) of 10 readings is
displayed. When the reading accuracy is 0%, “?” is
displayed for reading data.
<Reading Accuracy>
When coincidence judgment is ON:
<Header >
<Unit No.>
<Reading Data>
<FCS>
<Footer>
Coincident with registered data 0: 00
Coincident with registered data 1: 01
Coincident with registered data 2: 02
Coincident with registered data 3: 03
Not coincident with registered data 0 to 3: NG
<Number>
Send
Polling
<Footer>
<Unit No.>
Read the Scene Number Currently Displayed (@MS Unit No.)
1:N Connection
The displayed scene number (0 to 9) is output.
Send
<Footer>
<Unit No.>
Receive
Data is output from the V530-R150 without polling commands.
<Header >
<Unit No.>
<Scene No.>
<Footer>