The program is set up so that a rotary encoder (0000) controls execution of
SFT(10) through a DIFU(13), the rotary encoder is set up to turn ON and
OFF each time a product passes the first sensor. Another sensor (0002) is
used to detect faulty products in the chute so that the pusher output and HR
003 of the shift register can be reset as required.
Sensor
Chute
(0002)
(0500)
Sensor
(0001)
Rotary Encoder
(0000)
Pusher
0000
LD
0001
0001
LD
0000
0002
LD
0003
0003
SFT(10)
HR
0
HR
1
0004
LD
HR
003
0005
OUT
0500
0006
LD
0002
0007
OUT NOT
0500
0008
OUT NOT
HR
003
I
P
SFT(10)
HR 0
HR 1
R
0001
0000
0003
0500
HR 003
0002
HR 003
0500
Address
Instruction
Operands
5-12-2
REVERSIBLE SHIFT REGISTER – SFTR(84)
C : Control word
IR, DM, HR
St : Starting word
IR, DM, HR
Ladder Symbols
Operand Data Areas
E : End word
IR, DM, HR
SFTR(84)
C
St
E
St and E must be in the same data area and St must be less than or equal to
E.
Limitations
Data Shifting
Section 5-12