![background image](http://html.mh-extra.com/html/omron/sysmac-c20k/sysmac-c20k_operation-manual_1633423100.webp)
89
5.
T
2
and T
3
are made inoperative if IR 0015 is turned ON.
MOV(21)
#0400
06
First Cycle Flag
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
1
1
1
0
0
1
0
0
0
0
0
0
0
0
0
0
Content of IR O6 after MOV(21)
Range settings
1815
Address
Instruction
Operands
0000
LD
1815
0001
MOV(21)
#
0400
06
0606
0015
0607
0600
0002
0500
0100
0601
0003
0501
0101
0502
0102
0503
0103
0602
0004
0603
Used to inhibit operation of T
2
and T
3
.
T
0
started.
0500 turned ON when time for T
0
expires.
T
1
started.
0501 turned ON when time for T
1
expires.
T
2
and T
3
started.
0502 turned ON when time for T
2
expires.
0502 turned ON when time for T
3
expires.
T
0
Time Expired
Flag
T
0
Start Control Bit
T
1
Time Expired
Flag
T
2
Time Expired
Flag
T
3
Time Expired
Flag
T
1
Start Control Bit
T
2
Start Control Bit
T
3
Start Control Bit
Address
Instruction
Operands
0000
LD
0015
0001
OUT
0606
0002
OUT
0607
0003
LD
0002
0004
OUT
0600
0005
LD
0100
0006
OUT
0500
0007
LD
0003
0008
OUT
0601
0009
LD
0101
0010
OUT
0501
0011
LD
0004
0012
OUT
0602
0013
OUT
0603
0014
LD
0102
0015
OUT
0502
0016
LD
0103
0017
OUT
0503
Timer and Counter Instructions
Section 5-11