If CY is not set by executing SUB(31), the result is positive, the second sub-
traction is not performed and HR 300 is not turned ON. HR 300 is pro-
grammed as a self-maintaining bit so that a change in the status of CY will
not turn it OFF when the program is recycled.
CLC(41)
SUB(31)
10
DM 01
HR 2
CLC(41)
SUB(31)
#0000
HR 2
HR 2
TR 0
1904
HR 300
0002
1904
HR 300
First
subtraction
Second
subtraction
Turned ON to indicate
negative result.
0000
LD
0002
0001
OUT
TR
0
0002
CLC(41)
0003
@SUB(31)
10
DM
01
HR
2
0004
AND
1904
0005
CLC(41)
0006
@SUB(31)
#
0000
HR
2
HR
2
0007
LD
TR
0
0008
AND
1904
0009
OR
HR
300
0010
OUT
HR
300
Address
Instruction
Operands
5-16-3
BCD MULTIPLY – MUL(32)
Md : Multiplicand word (BCD)
IR, DM, HR, TC, #
Mr : Multiplier word (BCD)
IR, DM, HR, TC, #
Ladder Symbol
Operand Data Areas
MUL(32)
Md
Mr
R
R : First result word (BCD)
IR, DM, HR
R and R + 1 must be in the same data area.
Limitations
BCD Calculations
Section 5-16