5-4
5-2
V/f Control
H
Setting the V/f Patterns (n09 to n15)
•
Set the V/f pattern so that the motor output torque is adjusted to the required load torque.
•
The 3G3JV incorporates an automatic torque boost function. Therefore, a maximum of 150% torque
can be output at 3 Hz without changing the default settings. Check the system in trial operation and
leave the default settings as they are if no torque characteristic changes are required.
n09
Maximum Frequency (FMAX)
Changes during
operation
No
Setting
range
50.0 to 400 (Hz)
Unit of
setting
0.1 Hz
(See note 1.)
Default setting
60.0
n10
Maximum Voltage (VMAX)
Changes during
operation
No
Setting
range
1 to 255 (V) (See note 2.)
Unit of
setting
1 V
Default setting
200 (See
note 2.)
n11
Maximum Voltage Frequency (FA)
Changes during
operation
No
Setting
range
0.2 to 400 (Hz)
Unit of
setting
0.1 Hz
(See note 1.)
Default setting
60.0
n12
Middle Output Frequency (FB)
Changes during
operation
No
Setting
range
0.1 to 399 (Hz)
Unit of
setting
0.1 Hz
(See note 1.)
Default setting
1.5
n13
Middle Output Frequency Voltage (VC)
Changes during
operation
No
Setting
range
1 to 255 (V) (See note 2.)
Unit of
setting
1 V
Default setting
12 (See
note 2.)
n14
Minimum Output Frequency (FMIN)
Changes during
operation
No
Setting
range
0.1 to 10.0 (Hz)
Unit of
setting
0.1 Hz
Default setting
1.5
n15
Minimum Output Frequency Voltage (VMIN)
Changes during
operation
No
Setting
range
1 to 50 (V) (See note 2.)
Unit of
setting
1 V
Default setting
12 (See
note 2.)
Note 1.
Values will be set in 0.1-Hz increments if the frequency is less than 100 Hz and 1-Hz incre-
ments if the frequency is 100 Hz or greater.
Basic Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3JV-A4002
Page 1: ...USER S MANUAL SYSDRIVE 3G3JV Compact Simplified Inverters Cat No I528 E1 04...
Page 3: ...USER S MANUAL Compact Simplified Inverter SYSDRIVE 3G3JVSERIES...
Page 16: ......
Page 20: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 26: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 57: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 65: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 216: ...Chapter 10 List of Parameters 10...
Page 229: ...Chapter 11 Using the Inverter for a Motor 11...