![Omron SYSDRIVE 3G3JV-A4002 User Manual Download Page 122](http://html1.mh-extra.com/html/omron/sysdrive-3g3jv-a4002/sysdrive-3g3jv-a4002_user-manual_742832122.webp)
7-6
Set Values
Value
Description
0
0.1 Hz
1
0.01 Hz
2
Converted value based on 30,000 as max. frequency
3
0.1% (Max. frequency: 100%)
Note
Communications data after the above conversion is hexadecimal.
For example, if the frequency is 60 Hz and the unit of setting is 0.01 Hz, the converted value is
obtained as follows:
60/0.01 = 6000 = 1770 Hex
H
Slave Address (n70)
•
Set this parameter to the Slave address (Slave unit number) for communications.
•
If more than one Inverter is connected as a Slave, make sure that there will be no Slave address
duplication.
n70
RS-422A/485 Communications
Slave Address
Register
0146 Hex
Changes during
operation
No
Setting
range
00 to 32
Unit of
setting
1
Default setting
00
Set Values
Value
Description
00
Only receives broadcast messages from the Master (See note.)
01 to 32
Slave address
Note
Address 00 is for broadcast purposes only. Do not set the Slave to this address, otherwise the
Slave will not communicate.
H
Communications Baud Rate and Parity Selection (n71 and n72)
•
Set the baud rate and parity according to the communications conditions of the Master.
n71
RS-422A/485 Baud Rate Selection
Register
0147 Hex
Changes during
operation
No
Setting
range
0 to 3
Unit of
setting
1
Default setting
2
Set Values
Value
Description
0
2,400 bps
1
4,800 bps
2
9,600 bps
3
19,200 bps
Communications
Chapter 7
Summary of Contents for SYSDRIVE 3G3JV-A4002
Page 1: ...USER S MANUAL SYSDRIVE 3G3JV Compact Simplified Inverters Cat No I528 E1 04...
Page 3: ...USER S MANUAL Compact Simplified Inverter SYSDRIVE 3G3JVSERIES...
Page 16: ......
Page 20: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 26: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 57: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 65: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 216: ...Chapter 10 List of Parameters 10...
Page 229: ...Chapter 11 Using the Inverter for a Motor 11...