![Omron SYSDRIVE 3G3JV-A4002 User Manual Download Page 58](http://html1.mh-extra.com/html/omron/sysdrive-3g3jv-a4002/sysdrive-3g3jv-a4002_user-manual_742832058.webp)
3-2
3-1
Nomenclature
Data display
Keys
Indicators
Setting/Monitor item indicators
FREQ adjuster
Appearance
Name
Function
Data display
Displays relevant data items, such as frequency reference,
output frequency, and parameter set values.
FREQ adjuster
Sets the frequency reference within a range between 0 Hz
and the maximum frequency.
FREF indicator
The frequency reference can be monitored or set while this
indicator is lit.
FOUT indicator
The output frequency of the Inverter can be monitored
while this indicator is lit.
IOUT indicator
The output current of the Inverter can be monitored while
this indicator is lit.
MNTR indicator
The values set in U01 through U10 are monitored while
this indicator is lit.
F/R indicator
The direction of rotation can be selected while this
indicator is lit, when operating the Inverter with the RUN
Key.
LO/RE indicator
The operation of the Inverter through the Digital Operator
or according to the parameters set is selectable while this
indicator is lit.
Note
This status of this indicator can be only monitored
while the Inverter is in operation. Any RUN command
input is ignored while this indicator is lit.
PRGM indicator
The parameters in n01 through n79 can be set or
monitored while this indicator is lit.
Note
While the Inverter is in operation, the parameters can
be only monitored and only some parameters can be
changed. The RUN command input is ignored while
this indicator is lit.
Mode Key
Switches the setting and monitor item indicators in
sequence.
Parameter setting being made is canceled if this key is
pressed before entering the setting.
Increment Key
Increases multi-function monitor numbers, parameter
numbers, and parameter set values.
Decrement Key
Decreases multi-function monitor numbers, parameter
numbers, and parameter set values.
Preparing for Operation and Monitoring
Chapter 3
Summary of Contents for SYSDRIVE 3G3JV-A4002
Page 1: ...USER S MANUAL SYSDRIVE 3G3JV Compact Simplified Inverters Cat No I528 E1 04...
Page 3: ...USER S MANUAL Compact Simplified Inverter SYSDRIVE 3G3JVSERIES...
Page 16: ......
Page 20: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Page 26: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 57: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Page 65: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 216: ...Chapter 10 List of Parameters 10...
Page 229: ...Chapter 11 Using the Inverter for a Motor 11...