Communication protocols
4.1
Available interfaces
The Trajexia units have these interfaces to communicate:
/i
4.2
Ethernet
The TJ2-MC64 has a standard 10/100 Mbps Ethernet port. You can use a
crossover or a patch Ethernet cable to connect the TJ2-MC64 to a PC.
To configure the interface, set these parameters:
/i
Make sure that the IP address of the PC is in the same range as the TJ2-
MC64: if the IP address of the TJ2-MC64 is
aaa.bbb.ccc.ddd
, the IP address
of the PC must be
aaa.bbb.ccc.xxx
, where
xxx
is 000 to 255 other than
ddd
.
You can change the IP address of the TJ2-MC64 to match the IP address of
your PC if you connect to the PC through a network hub or switch. For
example, if the IP address of the PC is 192.200.185.001, you can set the IP
address of the TJ2-MC64 to 192.200.185.002.
Unit
Interface
Protocol
Comment
TJ2-MC64
Ethernet
Trajexia Studio protocol
To program, monitor and debug
the project with Trajexia Studio.
FINS server
To communicate with any FINS
master, for example PLC, HMI, or
personal computer.
FINS client
To communicate to any FINS
server, for example PLC or
another Trajexia unit.
ModbusTCP
To respond to any ModbusTCP
request, for example a PLC unit.
EtherNet/IP
To respond to any EtherNet/IP
request.
Serial
Host Link Master
To communicate with any Host
Link slave, for example an
OMRON PLC.
Host Link Slave
To communicate with any Host
Link master, HMI typically.
ModbusRTU slave
To communicate with any Mod-
busRTU master.
User defined
This protocol is created and han-
dled using BASIC commands.
TJ1-PRT
PROFIBUS
PROFIBUS Slave DP-V0
To exchange word variables with
any PROFIBUS master.
TJ1-DRT
DeviceNet
DeviceNet
To exchange word variables with
any DeviceNet master.
TJ1-CORT
CANopen
CANopen
To exchange word variables within
a CANopen network.
TJ1-ML__
MECHATRO-
LINK-II
MECHATROLINK-II
To communicate with supported
MECHATROLINK-II slaves. This
protocol is transparent to the user.
Item
Default value
Comment
IP address
192.168.0.250
Set one IP address that is unique in the network.
Subnet mask
255.255.255.0
Set the same subnet that the LAN uses.
Gateway
0.0.0.0
The gateway is necessary to have remote access
from another LAN.
Note
The above is true if the subnet mask setting is the factory setting,
that is, the subnet mask is not changed.
Note
The TJ2-MC64 does not have DHCP functionality, therefore it can-
not assign an IP address to a PC.
Unit
Interface
Protocol
Comment