MTYPE
Contains the type of move currently being executed.
NTYPE
Contains the type of the move in the Next Move buffer.
OFFPOS
Contains an offset that will be applied to the demand position
without affecting the move in any other way.
OPEN_WIN
Defines the beginning of the window in which a registration
mark is expected.
OUTLIMIT
Contains the limit that restricts the speed reference output from
the TJ2-MC64.
OV_GAIN
Contains the output velocity control gain.
P_GAIN
Contains the proportional control gain.
RAISE_ANGLE
Defines the angle change in radians above which an X-Y sys-
tem will interact with a BASIC program.
REG_POS
Contains the position at which the (primary) registration event
occurred.
REG_POSB
Contains the position at which the secondary registration event
occurred.
REGIST_SPEED
Contains the speed when the (primary) registration event
occurred.
REGIST_SPEEDB
Contains the speed when the secondary registration event
occurred.
REMAIN
Is the distance remaining to the end of the current move.
REP_DIST
Contains or sets the repeat distance.
REP_OPTION
Controls the application of the REP_DIST axis parameter.
REV_IN
Contains the input number to be used as a reverse limit input.
REV_JOG
Contains the input number to be used as a jog reverse input.
RS_LIMIT
Contains the absolute position of the reverse software limit.
S_REF
Contains the speed reference value which is applied when the
axis is in open loop.
S_REF_OUT
Contains the speed reference value being applied to the Servo
Drive for both open as closed loop.
Name
Description
SERVO
Determines whether the axis runs under servo control or open
loop.
SPEED
Contains the demand speed in units/s.
SPEED_SIGN
Configures the voltage range of the analog speed reference out-
put of the TJ1-FL02.
SRAMP
Contains the S-curve factor.
START_DIR_LAST
Defines the start direction in radians of the last programmed
forced speed move of 2 or more axes.
STOP_ANGLE
Defines the angle change in radians above which an X-Y sys-
tem should decelerate to zero speed.
T_REF
Contains the torque reference value which is applied to the
servo motor.
TABLE_POINTER
Parmeter to determine which
TABLE
memory location is cur-
rently being used by the
CAM
.
TANG_DIRECTION
Parameter returns the angle in radians that represents the vec-
tor direction of the interpolated axes.
TRANS_DPOS
Contains axis demand position at output of frame transforma-
tion.
UNITS
Contains the unit conversion factor.
VECTOR_BUFFERED
Holds the total vector length of the buffered moves.
VFF_GAIN
Contains the speed feed forward control gain.
VP_SPEED
Contains the speed profile speed.