SmartController EX User's Guide
11069-000 Rev. H
4.5 Connecting User-Supplied Safety and Power-Control Equipment
Pin
Pairs
Description
Comments
5, 18
Muted Safety Gate CH 1 (causes E-
Stop in Automatic mode only)
N/C contacts, Shorted if NOT Used
6, 19
Muted Safety Gate CH 2 (same as
pins 5, 18)
N/C contacts, Shorted if NOT Used
Voltage-Free Contacts provided by the System
7, 20
E-Stop indication CH 1
Contacts are closed when Front Panel,
pendant, and customer E-Stops are
not
tripped
8, 21
E-Stop indication CH 2 (same as
pins 7, 20)
Contacts are closed when Front Panel,
pendant, and customer E-Stops are
not
tripped
9, 22
Manual / Automatic indication CH 1
Contacts are closed in Automatic mode
10, 23
Manual / Automatic indication CH 2
Contacts are closed in Automatic mode
11, 12,
13, 24,
25
No connection