![Omron SmartController EX User Manual Download Page 38](http://html.mh-extra.com/html/omron/smartcontroller-ex/smartcontroller-ex_user-manual_1633417038.webp)
38
SmartController EX User's Guide
11069-000 Rev. H
4.5 Connecting User-Supplied Safety and Power-Control Equipment
Table 4-8. Remote Pendant Connections on the XMCP Connector
Pin XMCP
(15-Pin D-Sub)
Description
1, 9
Pendant E-Stop Push-button CH 1
2, 10
Pendant E-Stop Push-button CH 2
3, 11
Pendant Enable CH 1 (Hold-to-run)
4, 12
Pendant Enable CH 2 (Hold-to-run)
13
Serial GND / Logic GND
7
Pendant TXD: “eV+ to Pendant TXD”
8
Pendant RXD: “eV+ to Pendant RXD”
14
No connection
15
No connection
Shield
Shield GND
6
24 V
5
No connection
Table 4-9. XSYS Connector Pin Assignments
Pin
Signal
Description
1
ESTOPGND
GND Return
2
MANUAL1
Manual Mode ESTOP Ckt. CH 1
3
MANUAL2
Manual Mode ESTOP Ckt. CH 2
4
HIPWRDIS
High Power Disable
5
HIPWRREQ
High Power Request
6
AUTO1
Auto Mode ESTOP Ckt. CH 1
7
AUTO2
Auto Mode ESTOP Ckt. CH 2
8
N/C
No Connection
9
ESTOPSRC
24 V Output to Slave ESTOP
NOTE:
The XSYS connector is used to link the E-Stop system to our robots. It is
not intended for customer connections.