54
Whenever the screen number registered for history attributes is designated
by the host, the occurrence and message are saved in memory.
•
The capacity of the history is 256 screens.
•
The only things that can be recorded are screen numbers and messages.
History record data is backed up by a battery, so, as long as the lithium bat-
tery is installed, the contents will be retained even when the power is turned
off.
•
Before beginning to record, initialize the history data by transmitting an Ini-
tialize History command from the host, or by selecting Init. Hist. from the
Maintenance Mode.
•
If the history data capacity is exceeded, newly occurring history data will not
be saved.
Reading History Data
Enter Maintenance Mode from the System Menu.
Quit
MAINTENANCE MENU
I/O Check
PT Settings
Init. Screen
Init. Hist.
Quit
Display Hist.
Move the bar cursor to History Record by pressing the Up and Down Keys.
Then press the Enter Key.
History Record
Frequency
Occurrence
Select whether the history is to be displayed in order of occurrence or in or-
der of frequency. First move the bar cursor to your selection by means of the
Up and Down Keys, and then press the Enter Key.
Order of Occurrence
Record data is displayed in order of occurrence.
No.
1
5
200
150
Times
( )
( )
( )
( )
Message
Coolant Mal.
Motor Mal.
Comp. Mal.
Press
Number of times occurred.
Screen number
Of
Maintenance Mode
Section 6-3