4-5
Numeric Displays
A numeral table is stored in the PT, and you can display numeric values from
the table at programmed positions on a screen. In addition, the values in the
table can be transferred from the host so that they are renewed each time a
new value is transferred. The display positions are set in advance with the
Support Tool.
Example
Screen Registered
Production
Line 1
Weld
Assem
No.
Contents
These contents are transmitted from the host.
When the PC is used as the host, for example, these values will be transferred via the Host
Interface Unit and updated on screen when the contents of the DM Area are changed.
Final
Paint
Line 2
# 1
# 2
# 3
# 4
# 5
# 6
# 7
# 8
# 1
1020
# 2
832
# 3
711
# 4
630
# 5
556
# 6
999
# 7
807
# 8
777
Screen Displayed
Production
Line 1
Weld
Assem
Final
Paint
Line 2
1020
832
711
630
556
999
807
777
Contents registered to screens by Support Tool:
Numeral table numbers
Display positions
Number of digits displayed (whole numbers, fractions)
Sizes of characters displayed
Numeral Table
(Maximum of 128 entries)
Numeric Displays