27
Plug:
XM2A-0901 (OMRON) or equivalent.
Hood:
XM2S-0911 (OMRON) or equivalent.
Recommended Cables
AWG 28 x 5P IFVV-SB (Fujikura Cable, Ltd.)
CO-MA-VV-SB 5P x 28 AWG (Hitachi Cable, Ltd.)
Cable Set
CV500-CN228 (OMRON)
Cable length: 2 m
2-7
Mounting Function Key Units (to DN-type PTs)
Mounting Procedure
1, 2, 3...
1. Remove the rubber packing and bottom connector seal from the DN-type
PT.
2. Mount the 12-key Function Key Unit to the PT, matching the connectors. Us-
ing a Phillips screwdriver, tighten the five mounting screws.
NT20M-DN
jjj
Programmable Terminal
Phillips screwdriver
NT20M-FK210 12-key
Function Key Unit
Mounting screws (5 places)
3. Attach the rubber packing that comes with the 12-key Function Key Unit.
Rubber packing
4. Mount to the panel.
Applicable Connectors
(Cable Side)
Mounting Function Key Units (to DN-type PTs)
Section 2-7