Number of settings: The total number of lamps must not be greater than
64 per screen.
Display attribute:
Lit or flashing (used for bit designation).
Guide characters:
With or without (selectable).
Lamps set from the host can be turned on and off by either of two methods:
number designation or bit designation. For details, refer to the Host Interface
Unit Operation Manual.
If using a lamp together with a switch, then set the lamp within the switch
frames, of which there are 12 horizontal and 6 vertical.
Example 2: Emphasis
The display of the number defective can be emphasized setting it to blink.
Goal
Complete
Defective
1234
600
2
4-9
Graphics Display
Unbroken straight lines (polylines) and circles can be created by the Support
Tool and displayed at the PT. When an RS-232C or RS-422 Interface Unit is
used, the graphics can be displayed by using the terminal function and trans-
mitting commands from the host. (The terminal function can be used with all
versions. See 4-10-7 Terminal Function.)
Graphics display positions can be designated in dot units. In cases where
graphics and characters overlap, the graphics will be overwritten. Polylines
and circles are both drawn with a width of one dot.
4-10
Special Controls
The status of the PT can be controlled from the host during operation.
4-10-1
Backlight On/Off
In order to prolong the life of the backlight, the backlight can be set to turn off
when it is not needed during operation.
Example 1: Usage with
Switch Frames
Designating Display
Positions
Special Controls