40
4-6
Character Strings
This function displays variable character strings on the screen. These char-
acter strings can be changed with transmissions from the host. A character
string memory table is stored in the PT. By changing, from the host, the
memory table values corresponding to the display position, you can update
the characters displayed. The designation of the display positions is set in
advance at the Support Tool.
Example
Screen Registered
Production
Line 1
Weld
Assem
Contents registered to screens by Support Tool:
Character string memory table numbers
Display positions
Number of characters displayed
Sizes of characters displayed
No.
Contents
These contents are transmitted from the host.
When the PC is used as the host, for example, these values will be transferred via the Host
Interface Unit and updated on screen when the contents of the DM Area are changed.
Final
Paint
Line 2
# 1
# 2
# 3
# 4
# 5
# 6
# 7
# 8
# 1
Van
# 2
Car A
# 3
Car B
# 4
High-roof
# 5
Sports A
# 6
Convert
# 7
# 8
Screen Displayed
Production
Line 1
Weld
Assem
Final
Paint
Line 2
Van
Car A
Car B
High-roof
Sports A
Convert
Character String Table
(Maximum of 32 entries)
Character Strings
Section 4-6