Erasing keys
Section 7-1
66
7-1
Erasing keys
If necessary, It is possible to erase an application or firmware in the NQ-
Series. The corners of the touch screen are used for erasing.
Figure 7.1: Erasing keys
1 Erase firmware
2 Erase application
3 Confirm
4 Starting FWHT and system set-up
To erase an application proceed as follows.
• Press the top right corner of the touch screen for 2 seconds during power-
on.
• The following message is displayed:
Application Erase Mode... Press at
Bottom Right corner to confirm
. Press the bottom right button to confirm.
• After erasing the program the following message is displayed:
No setup
loaded. Download application.
To erase the firmware proceed as follows.
• Press the top left corner of the touch screen for 2 seconds during power-
on.
• The following message is displayed:
Firmware Erase Mode... Press at
Bottom Right corner to confirm
. Press the bottom right button to confirm.
• After erasing the firmware the following message is displayed:
No
firmware.... Download firmware.
If the NQ-Series does not function correctly, erase the application and
download a demo program. If the NQ-Series functions correctly, it is possible
the previous application was incorrect.
Summary of Contents for NQ HMI
Page 1: ...NQ Series HMI GETTING STARTED GUIDE Cat No V07 EN 01 NQ3 TQ0 B NQ3 MQ0 B NQ5 SQ0 B NQ5 MQ0 B...
Page 2: ......
Page 6: ......
Page 14: ...Conformance to EC Directives Section 1 7 xiii...
Page 20: ...Specifications per model Section 2 4 6...
Page 78: ...Debugging Section 6 2 64...
Page 88: ...NQ Series diagnostics Section 7 4 74...
Page 144: ...130...