148
LD Cart Transporter User's Manual
14766-000 Rev H
10.2 Safety Measures Prior and After Maintenance
Magnetic Field Hazards
Platform Covers
!
WARNING:
MAGNETIC FIELD - MEDICAL IMPLANT RISK
Magnetic fields can be hazardous to medical implant wearers. Medical
implant wearers stay back 30 cm (12 inches) from the covers, which are held in
place with strong magnets.
Docking Funnel
!
WARNING:
MAGNETIC FIELD - MEDICAL IMPLANT RISK
Magnetic fields can be hazardous to medical implant wearers. Medical
implant wearers stay back 30 cm (12 inches) from the underside of the plat-
form, which is exposed during certain maintenance procedures for which the
platform is tipped on its side.
10.2 Safety Measures Prior and After Maintenance
Prior to performing maintenance work (safety inspection, cleaning, removing parts, installing
parts, etc.), following safety measures must be taken:
l
Ensure that the AMR has come to a complete stop, by pressing the E-Stop button on the
Operator Panel
l
Power OFF the AMR by pressing the OFF button on the Operator Panel
Once maintenance work has completed, and the AMR is ready for use, take following actions:
l
Power ON the AMR by pressing the ON button on the Operator Panel
l
Release the E-Stop
10.3 Lifting the Platform Safely
If, for any reason, you need to lift the platform by hand, take care to lift from safe lifting points.
!
WARNING:
PROPERTY DAMAGE RISK
Lifting the platform from the wrong points can damage the platform.
Front Lifting Points
On each side of the laser, under the upper side of the laser slot. Do not lift at the center - there
is no frame supporting it there. Do not lift anywhere else! Refer to the following illustration: