Operation manual
G9SR
Page 60 of 79
11.1.5
G9SR-
BC□
-
□ with
Safety Sensors in applications up to PL
e (F3S
-TGR-CL)
Settings G9SR-BC:
•
Manual Restart enabled
•
EDM enabled
•
Dynamic Input Test disabled
•
Aux inverted
Dip switch settings: 1
2
3
4
5
6
7
8
OFF OFF ON
OFF OFF OFF OFF OFF
Description:
Safety Sensor connected to T12 and T22
Restart pushbutton connected to T31
KM1 and KM2: Motor Contactors
Feedback loop (EDM) connected to T32
Remarks:
This setup can also be used for all sensors with solid state safety outputs
Applicable up to PLe acc. EN ISO 13849-1 (electrical system).
Motor circuit (contacts of KM1 and KM2) not shown.