7
G9SR unit: G9SR-
AD□
-
□
7.1
Introduction
The G9SR-
AD□
-
□ unit can handle one double
-channel input
device and 2 output signals.
The outputs are switched with relays designed for 250V AC with
switching currents:
Max. 4A AC1*
Max. 5A AC15
Max. 4A DC1*
Max. 5A DC13
*
See also § 4.2
This unit can be expanded with:
•
up to 3 G9SR-
EX□
-
□
-
□
units to increase the output signal
capabilities.
See also § 10.1
on page 49
•
up to 2 G9SR-
BC□
-
□ units to increase the input signal capabilities.
See also § 10.2
on page 50
7.2
Internal connections of G9SR-
AD□
-
□
Power
supply
circuit
Safety
Input 1
Safety
Input 2 Restart
EDM
Safety Output
Control
Auxiliary Output
Control
IN
Loop
OUT
Loop
K1
K2
K1
K2
A1
T11 T12 T21 T22
T31
T32
13
23
T44
T41
T43
T42
A2
44
14
24
Figure 3 - Internal connections of G9SR-AD
□
-
□