Operation manual
G9SR
XXV
GLOSSARY, DEFINITIONS,
ABBREVIATIONS
Aux.:
Aux
iliary. E.g. Auxiliary Outputs
Dynamic Input testing:
Test if the separate input channels are connected (shorted).
Applicable to G9SR-
BC□
-
□ and G9SR
-
AD□
-
□
EDM:
E
xternal
D
evice
M
onitoring;
Active checking of the correct behavior of external connected units
like safety relays.
ESPE:
E
lectro
S
ensitive
P
rotective
E
quipment
Assemblies of
•
a sensing device
•
controlling/monitoring devices
•
Output Signal Switching Device (OSSD)
FA:
F
actory
A
utomation
G9SR-
BC□
-
□:
A Basic unit (BC) of the G9SR series.
G9SR-
AD□
-
□:
An Advanced unit (AD) of the G9SR series.
G9SR-
EX□
-T90-
□:
An Extension unit (EX) of the G9SR series.
Input:
Signal going into the unit. Input signals can come from e.g. safety
sensors, E-stop switches or SLCs.
Lock out State:
A forced OFF state, the OSSDs are OFF. This state can be reached
when an error occurs in the complete system.
Power cycle the unit to exit this State.
MPU:
M
icro
P
rocessing
U
nit.
NO / NC:
N
ormally
O
pened
/ N
ormally
C
losed
The contact situation of switching devices (switches, relays,..)
when not powered/activated.
OSSD:
O
utput
S
ignal
S
witching
D
evice.
OSSD can be safety relays with mechanical contacts or solid state
outputs such as PNP-transistors.
Summary of Contents for G9SR
Page 1: ...ZX T Series Cat No J12E EN 03 G9SR Safety Relays OPERATION MANUAL G9SR BC G9SR AD G9SR EX...
Page 34: ...Operation manual G9SR Page 8 of 79 3 1 Test the OFF behaviour...
Page 35: ...Operation manual G9SR Page 9 of 79 3 2 Test the ON behaviour...
Page 102: ...Operation manual G9SR Page 76 of 79 My notes...
Page 105: ...Operation manual G9SR Page 79 of 79 My notes...