![background image](http://html1.mh-extra.com/html/omron/f250/f250_setup-manual_741266059.webp)
55
F250
Setup Manual
SECTION 5
Troubleshooting and Maintenance
SE
CTION 5
Q&A
Q&A
Cameras
Questions
Answers
Are the shutter trigger
pulses synchronized when
more than one camera is
connected?
The shutter trigger pulses are not synchronized for the F160-S2 and
F150-S1A.
The timing is offset so that light from other Cameras does not enter.The
offset depends on the model of Camera that is used.
If a strobe is used, the strobe trigger signals are also offset in the same
way as the shutter trigger pulses.
The shutter trigger pulses are synchronized for other Cameras, i.e., there
is no offset.
Can more than one
internally synchronized
Cameras be connected?
No.Only one internally syncronized Camera can be connected, and it must be
connected to Camera connector 0.
Can the F150-LT10A Light
be connected to the F160-
S2 Camera?
Yes, it can be connected and the following Lenses are available.
•
Lens with 20 mm field of vision: F150-LE20
•
Lens with 50 mm field of vision: F150-LE50
F160-S2
F150-S1A
tD=Approx.
500 µs
tD=Approx.
1 ms
Camera 0
Camera 1
Camera 2
Camera 3
tD
: Shutter trigger pulses ON