CHAPTER 2 CompoWay/F COMMUNICATIONS PROCEDURES
E5AN/EN/CN/GN
2--14
This service carries out run/stop, communications writing, write mode,
save RAM data, AT (auto-tuning) execution/cancel, multi-SP, move to pro-
tect level, move to setup area 1 and software reset.
MRC SRC
3 0 0 5
2
2
MRC SRC
Response
code
3 0 0 5
2
2
4
Instruc-
tion code
Related
informa-
tion
2
2
Service request PDU
Service response PDU
(1) Instruction code and related information
Instruction
code
Description
Related information
00
Communications writing
00: OFF (disabled)
01: ON (enabled)
01
Run/Stop
00: Run
01: Stop
02
Multi-SP
00: Set point 0
01: Set point 1
02: Set point 2
03: Set point 3
03
AT execute/cancel
00: Cancel
01: AT execute
04
Write mode
00: Backup
01: RAM
05
Save RAM data
00
06
Software reset *
00
07
Move to setup area 1
00
08
Move to protect level
00
* No response will be returned when a software reset is carried out.
(2) Response code
At normal completion
Response code
Name
Description
0000
Normal completion
No errors were found.
J
Operation
instructions