This service reads the run status of the controller.
MRC SRC
Response
code
0 6 0 1
2
2
4
MRC SRC
0 6 0 1
2
2
Run
status
Related
informa-
tion
2
2
Service request PDU
Service response PDU
(1) Run status
Run status
Description
00
Control is being carried out (error has not occurred in setup area
0, and the controller is running).
01
Control is not being carried out (state other than above).
(2) Related information
0
0
7
0
6
5
4
3
1
2
Bit position
Heater overcurrent
Heater current hold
HB (HBA display) error
Display range exceeded
Input error
0
(3) Response code
At normal completion
Response code
Name
Description
0000
Normal completion
No errors were found.
At occurrence of error
Response code
Name
Description
1001
Command too long
The command is too long.
2203
Operation error
EEPROM error
J
Read controller