background image

1

New Product

Digital Temperature Controller

E5

C/E5

C-T

The E5

C Series Temperature Controller provides a wide lineup of 

models to meet a variety of applications. These controllers are easy to 

setup and operate, have unique performance capabilities and offer 

excellent visibility.

Programmable Digital Temperature Controllers: E5□C-T Series

Digital Temperature Controllers: E5□C Series

1/32 DIN 

Panel Mount

48 × 24 mm

1/8 DIN 

Panel Mount

48 × 96 mm

1/4 DIN

Panel Mount

96 × 96 mm

E5GC

E5CC

E5CC-B

E5CC-U

E5EC

E5EC-B

E5AC

E5DC

E5DC-B

E5CC-T

E5EC-T

E5AC-T

DIN 22.5 mm wide 
Controllers That 
Mount to 
DIN Track

1/16 DIN 

Panel Mount

48 × 48 mm

1/8 DIN

Panel Mount

48 × 96 mm

1/4 DIN

Panel Mount

96 × 96 mm

Models with Screw Terminal Blocks

Models with 
Push-In Plus Terminal Blocks

Plug-in Models

Models with Screw Terminal Blocks/
Models with Screwless Clamp 
Terminal Blocks

Models with Screw Terminal Blocks

Models with Screw Terminal Blocks

Models with Screw Terminal Blocks

Models with Screw Terminal Blocks

Models with Screw Terminal Blocks

Models with Screw Terminal Blocks

Models with 
Push-In Plus Terminal Blocks

Models with 
Push-In Plus Terminal Blocks

1/16 DIN 

Panel Mount

48 × 48 mm

page 18

page 40

page 40

page 58

page 78

page 96

page 96

page 2

page 40

page 18

page 18

page 58

Summary of Contents for E5 C Series

Page 1: ...EC T E5AC T DIN 22 5 mm wide Controllers That Mount to DIN Track 1 16 DIN Panel Mount 48 48 mm 1 8 DIN Panel Mount 48 96 mm 1 4 DIN Panel Mount 96 96 mm Models with Screw Terminal Blocks Models with P...

Page 2: ...tion on applicable safety standards 48 24 mm Models with Screwless Clamp Terminal Blocks E5GC C CSA conformance Event Inputs None 1 Control Output 1 Relay output Voltage output for driving SSR Linear...

Page 3: ...131 Heating and Cooling Control Using Heating and Cooling Control A Control Output Assignment An auxiliary output is used as the cooling control output B Control If PID control is used you can set PID...

Page 4: ...Waterproof Packing Note This Waterproof Packing is provided with the Digital Temperature Controller Draw out Jig CX Thermo Support Software Note CX Thermo version 4 62 or higher is required for the E5...

Page 5: ...tions Minimum applicable load 10 mA at 5 V reference value Event input Number of inputs 1 or 2 depends on model External contact input specifications Contact input ON 1 k max OFF 100 k min Non contact...

Page 6: ...ture sensor Sensor specification Pt100 JPt100 K J T E L U N R S B C W PLII 10 to 70 C 60 to 120 C 115 to 165 C 140 to 260 C 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 30...

Page 7: ...equence A standby sequence is added to the lower limit alarm 3 6 8 Absolute value upper limit The alarm will turn ON if the process value is larger than the alarm value X regardless of the set point 9...

Page 8: ...to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the operation of the standby sequence 7 Refer to the E5 C Digital Temperature Controllers User s Manual Cat No...

Page 9: ...or F Analog input 0 1 to 999 9 FS in units of 0 1 FS Integral time I 0 to 9999 s in units of 1 s 0 0 to 999 9 s in units of 0 1 s 5 Derivative time D 0 to 9999 s in units of 1 s 0 0 to 999 9 s in uni...

Page 10: ...icing Storage humidity 10 to 80 Altitude 2 000 m max Weight Approx 120 g Transmission line connection method RS 485 Multidrop Communications RS 485 two wire half duplex Synchronization method Start s...

Page 11: ...puts Control Outputs Auxiliary outputs 1 2 Terminal type The E5GC is set for a K type thermocouple input type 5 by default An input error s err wil occur if the input type setting does not agree with...

Page 12: ...crew Terminal Blocks M3 Screws 0 8 to 1 4 mm 8 to 12 mm 8 to 12 mm Controllers with Screwless Clamp Terminals Blocks Wire stripping length 8 to 12 mm Ferrules 8 to 12 mm E5GC C Controllers with Screwl...

Page 13: ...emperature Controller Group mounting does not allow waterproofing Mounting Adapter Accessory Y92F 53 also available for ordering separately Waterproof Packing Accessory Y92S P12 also available for ord...

Page 14: ...t together with the E58 CIFQ2 5 8 dia Two 3 5 dia 30 21 15 25 2 5 40 10 5 2 8 7 5 5 10 Filler epoxy Case E54 CT1 Thru current Io vs Output Voltage Eo Reference Values E54 CT1 or E54 CT1L Maximum conti...

Page 15: ...or E54 CT3L Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Digital Temperature Controller is 50 A Number of windings 400 2 Winding resistance 8 0 8 Thr...

Page 16: ...f the waterproof packing may occur depending on the operating environment Therefore periodic replacement is recommended to ensure the level of waterproofing specified in IP66 The time for periodic rep...

Page 17: ...17 MEMO...

Page 18: ...erminal Blocks E5CC B CSA conformance evaluation by UL Sensor Input Dual displays PV SV 4 digit displays E5CC E5CC B E5CC U Universal input Thermocouple Pt Analog current voltage Indication Accuracy T...

Page 19: ...ng and cooling It does not matter which output is used for heating and which output is used for cooling B Control If PID control is used you can set PID control separately for heating and cooling This...

Page 20: ...ntrol is used you can set PID control separately for heating and cooling This allows you to handle control systems with different heating and cooling response characteristics Model A B C D E F Meaning...

Page 21: ...inal type Input type Options E5CC 48 48 mm Control output 1 Control output 2 RW Relay output SPDT None QX Voltage output for driving SSR None CX Linear current output None 0 None 1 1 2 2 one common A...

Page 22: ...C U Front Covers CX Thermo Support Software Note CX Thermo version 4 5 or higher is required for the E5CC CX Thermo version 4 61 or higher is required for the E5CC U CX Thermo version 4 65 or higher i...

Page 23: ...250 VAC Models with 1 output 3 A resistive load E5CC U models with 2 outputs 3 A resistive load E5CC B models with 2 outputs 2 A resistive load Models with 3 outputs 2 A resistive load Electrical lif...

Page 24: ...thermometer Thermocouple Infraredtemperature sensor Sensor specification Pt100 JPt100 K J T E L U N R S B C W PLII 10 to 70 C 60 to 120 C 115 to 165 C 140 to 260 C 2300 1800 1700 1600 1500 1400 1300 1...

Page 25: ...alarm value X regardless of the set point 9 Absolute value lower limit The alarm will turn ON if the process value is smaller than the alarm value X regardless of the set point 10 Absolute value uppe...

Page 26: ...ion of the standby sequence 7 Refer to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the loop burnout alarm LBA 8 Refer to the E5 C Digital Temperature Controll...

Page 27: ...er 1 of indication value or 2 C whichever is greater 1 digit max Analog input 1 FS 1 digit max CT input 5 FS 1 digit max Remote SP input 1 FS 1 digit max Influence of voltage 3 Influence of EMS at EN...

Page 28: ...N IEC 61326 1 Table 2 Standards Approved standards cULus UL 61010 1 CSA C22 2 No 61010 1 8 KOSHA S Mark certification Some models only 9 Korean wireless regulations Radio law KC Mark Some models only...

Page 29: ...bient operating temperature 0 to 55 C with no condensation or icing Ambient operating humidity 10 to 80 Storage temperature 20 to 60 C with no condensation or icing Storage humidity 10 to 80 Altitude...

Page 30: ...h 3 auxiliary outputs 250 VAC 2 A resistive load no polarity 100 to 240 VAC 24 VAC DC Auxiliary outputs 1 2 3 7 8 9 10 Auxiliary output 2 Auxiliary output 3 Auxiliary output 1 005 Event Inputs 1 to 4...

Page 31: ...15 24 16 6 8 9 14 21 5 13 20 4 12 11 10 7 8 6 7 8 7 8 8 Pt A B B mA 7 6 V 7 V 6 TC 6 I 17 18 19 20 21 22 23 24 EV2 EV1 EV2 EV1 EV4 EV3 CT1 CT1 B A RS 485 B A RS 485 17 18 19 20 21 22 23 24 17 18 19 20...

Page 32: ...100 to 240 VAC 24 VAC DC no polarity RW CX Models with 1 Relay Output QX Models with 1 Voltage Output for Driving SSR Models with 1 Linear Current Output Output 1 Q Output 1 C Output 1 R E5CC UM 000 C...

Page 33: ...Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers To mount the Controller so that it is waterproof insert the water proof packing onto...

Page 34: ...ogether The Setup Tool port is on the top of the Temperature Controller It is used to connect the Temperature Controller to the computer to use the Setup Tool The E58 CIFQ2 USB Serial Conversion Cable...

Page 35: ...c replacement depends on the operating environment Be sure to confirm this point at your site Consider three years as a rough standard The E5CC U cannot be waterproofed even if the Waterproof Packing...

Page 36: ...54 CT3 or E54 CT3L Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Digital Temperature Controller is 50 A Number of windings 400 2 Winding resistance 8...

Page 37: ...nversion Cable if you use the Y92F 45 Adapter To use the USB Serial Conversion Cable to make the settings do so before you mount the Temperature Controller in the panel 4 You cannot use it together wi...

Page 38: ...ease use it for the mis operation prevention etc 40 0 2 4 5 5 6 7 8 4 3 2 1 9 10 11 70 max 4 Eleven M3 5 7 5 sems screws 7 8 Two 4 5 dia holes 50 max 3 31 2 max 35 4 Mounting Holes Terminal Layout Int...

Page 39: ...39 MEMO...

Page 40: ...6 mm Push In Plus Terminal Blocks E5EC B CSA conformance evaluation by UL E5EC E5EC B 4 digit displays Sensor Input Indication Accuracy Thermocouple input 0 3 of PV Pt input 0 2 of PV Analog input 0 2...

Page 41: ...cs Model A B C D E F Meaning Control outputs 1 and 2 No of auxiliary outputs Power supply voltage Terminal type Input type Options E5EC 48 96 mm E5AC 96 96 mm Control output 1 Control output 2 RX Rela...

Page 42: ...heating and cooling This allows you to handle control systems with different heating and cooling response characteristics Model A B C D E F Meaning Control outputs 1 and 2 No of auxiliary outputs Pow...

Page 43: ...h the Digital Temperature Controller Current Transformers CTs Lead wires are included with these CTs If UL certification is required use these CTs CX Thermo Support Software Note CX Thermo version 4 5...

Page 44: ...imum applicable load 10 mA at 5 V reference value Event input Number of inputs 2 4 or 6 depends on model External contact input specifications Contact input ON 1 k max OFF 100 k min Non contact input...

Page 45: ...temperature sensor Sensor specification Pt100 JPt100 K J T E L U N R S B C W PLII 10 to 70 C 60 to 120 C 115 to 165 C 140 to 260 C 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500...

Page 46: ...alarm value X regardless of the set point 9 Absolute value lower limit The alarm will turn ON if the process value is smaller than the alarm value X regardless of the set point 10 Absolute value upper...

Page 47: ...e standby sequence 7 Refer to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the loop burnout alarm LBA This setting cannot be used with a position proportional...

Page 48: ...f 0 1 C or F Analog input 0 1 to 999 9 FS in units of 0 1 FS Integral time I Standard heating cooling or Position proportional Close 0 to 9999 s in units of 1 s 0 0 to 999 9 s in units of 0 1 s Positi...

Page 49: ...0 to 55 C with no condensation or icing Ambient operating humidity 10 to 80 Storage temperature 20 to 60 C with no condensation or icing Storage humidity 10 to 80 Altitude 2 000 m max Weight Approx 1...

Page 50: ...rrent output 0 to 20 mA DC 4 to 20 mA DC Load 500 max 1 Control output Models with 1 Relay Output Models with 1 Voltage Output for Driving SSR Models with 2 Voltage Outputs for Driving SSR Models with...

Page 51: ...remote SP input Transfer output Remote SP input 4 event inputs and 1 CT input Communications 2 event inputs and 1 CT input Use no voltage inputs for the event inputs The polarity for non contact inpu...

Page 52: ...digit default setting Use the M Key to change to another parameter No 1 display No 2 display No 3 display PV or specified parameter SP or specified parameter value Top View of E5EC Top View of E5EC B...

Page 53: ...the specifications E5EC Selections for Control Outputs 1 and 2 QQ QR RR CC PR or CQ If you also specify 011 013 or 014 for the option selection and use group mounting the ambient temperature must be 4...

Page 54: ...rs To mount the Controller so that it is waterproof insert the waterproof packing onto the Controller When two or more Controllers are mounted make sure that the sur rounding temperature does not exce...

Page 55: ...on the front panel Setup Tool port of the E5EC E5EC B E5AC securely closed To maintain an IP66 degree of protection the Waterproof Packing and the Port Cover for the front panel Setup Tool port must...

Page 56: ...o vs Output Voltage Eo Reference Values E54 CT1 or E54 CT1L Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 18 2 Thru current Io A r m s 1 10 100mA 1 10 100...

Page 57: ...4 CT3 or E54 CT3L Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Digital Temperature Controller is 50 A Number of windings 400 2 Winding resistance 8 0...

Page 58: ...o read when setting up checking alarms and making settings in a control panel Main I O Functions Refer to Safety Precautions on page 122 Refer to your OMRON website for the most recent information on...

Page 59: ...utput 2 RX Relay output None QX Voltage output for driving SSR None 1 CX Linear current output 1 None 0 None 2 2 one common A 100 to 240 VAC D 24 VAC DC S Screw terminal blocks Main Unit and Terminal...

Page 60: ...onse characteristics List of Models Model A B C D E F Meaning Control outputs 1 and 2 No of auxiliary outputs Power supply voltage Terminal type Input type Options E5DC 22 5 mm wide and mounts to DIN...

Page 61: ...rt Software Note CX Thermo version 4 6 or higher is required for the E5DC CX Thermo version 4 69 or higher is required for the E5DC B For the system requirements for the CX Thermo refer to information...

Page 62: ...Output specifications SPST NO relay outputs 250 VAC 2 A resistive load Electrical life 100 000 operations Minimum applicable load 10 mA at 5 V reference value Event input 1 Number of inputs 1 depends...

Page 63: ...perature sensor Sensor specification Pt100 JPt100 K J T E L U N R S B C W PLII 10 to 70 C 60 to 120 C 115 to 165 C 140 to 260 C 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 40...

Page 64: ...by sequence A standby sequence is added to the lower limit alarm 3 6 8 Absolute value upper limit The alarm will turn ON if the process value is larger than the alarm value X regardless of the set poi...

Page 65: ...fer to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the operation of the standby sequence 7 Refer to the E5 C Digital Temperature Controllers User s Manual Cat...

Page 66: ...to 999 9 C or F in units of 0 1 C or F Analog input 0 01 to 99 99 FS in units of 0 01 FS Proportional band P Temperature input 0 1 to 999 9 C or F in units of 0 1 C or F Analog input 0 1 to 999 9 FS i...

Page 67: ...o 80 Storage temperature 20 to 60 C with no condensation or icing Storage humidity 10 to 80 Altitude 2 000 m max Weight Approx 120 g Transmission line connection method RS 485 Multidrop Communications...

Page 68: ...5 B A 3 4 RS 485 B A EV1 3 4 7 8 CT1 EV1 3 4 A B B 1 2 1 4 3 7 8 14 13 12 2 5 6 9 10 11 5 Sensor Temperature Analog Input Auxiliary output 2 Auxiliary output 1 1 Control Output 1 linear current output...

Page 69: ...1 12 15 16 Control output Relay output 250 VAC 3 A resistive load Voltage output for driving SSR 12 VDC 21 mA Linear current output 0 to 20 mA DC Load 500 max 4 to 20 mA DC Relay outputs 250 VAC 2 A r...

Page 70: ...er SP or specified parameter value No 1 display No 2 display Use the M Key to change to another parameter Use the U D Keys to set the parameter Press O Key for at least 3 seconds to go to Initial Sett...

Page 71: ...able operating temperature specified in the specifications The above figure shows the Terminal Unit attached to the Main Unit 4 86 90 110 6 5 96 22 5 6 5 22 5 1 15 0 2 90 1 15 0 2 4 35 90 Push In Plus...

Page 72: ...2 90 6 5 2110 250 263 1510 USB connector type A plug Serial connector LED SD LED PWR LED RD USB Serial Conversion Cable E58 CIFQ2 Connecting to the E58 CIFQ2 USB Serial Conversion Cable Conversion Cab...

Page 73: ...L Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 18 2 Thru current Io A r m s 1 10 100mA 1 10 100 1 000A 100V Frequency 50 Hz Distortion factor 10 3 1 100...

Page 74: ...CT3 or E54 CT3L Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Digital Temperature Controller is 50 A Number of windings 400 2 Winding resistance 8 0 8...

Page 75: ...oduct to connect between terminals for power supplies communications etc when you use multiple E5DC Controllers 50 11 5 10 M4 8 pan head screw M4 spring washer 4 8 1 3 1 8 1 10 6 2 1 8 35 5 35 3 4 5 1...

Page 76: ...over E53 COV26 E5DC B Push In Plus Terminal Units are mounted with both a male and female connector cover E53 COV26 Order the connector cover separately if it becomes lost or damaged Male connector co...

Page 77: ...77 MEMO...

Page 78: ...er to your OMRON website for the most recent information on applicable safety standards CSA conformance evaluation by UL Sensor Input Universal input Thermocouple Pt Analog current voltage E5CC T Dual...

Page 79: ...put is used for heating and which output is used for cooling B Control If PID control is used you can set PID control separately for heating and cooling This allows you to handle control systems with...

Page 80: ...l has already been prepared for an E5B Controller Waterproof Cover Mounting Adapter Note This Mounting Adapter is provided with the Digital Temperature Controller DIN Track Mounting Adapter Front Cove...

Page 81: ...le load 10 mA at 5 V reference value Event input Number of inputs 2 or 4 depends on model External contact input specifications Contact input ON 1 k max OFF 100 k min Non contact input ON Residual vol...

Page 82: ...ature sensor Sensor specification Pt100 JPt100 K J T E L U N R S B C W PLII 10 to 70 C 60 to 120 C 115 to 165 C 140 to 260 C 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 3...

Page 83: ...sequence A standby sequence is added to the lower limit alarm 3 6 8 Absolute value upper limit The alarm will turn ON if the process value is larger than the alarm value X regardless of the set point...

Page 84: ...mable Type User s Manual Cat No H185 for information on the operation of the standby sequence 7 Refer to the E5 C T Digital Temperature Controllers Programmable Type User s Manual Cat No H185 for info...

Page 85: ...FS Proportional band P Temperature input 0 1 to 999 9 C or F in units of 0 1 C or F Analog input 0 1 to 999 9 FS in units of 0 1 FS Integral time I 0 to 9999 s in units of 1 s 0 0 to 999 9 s in units...

Page 86: ...unction Select from ramp SP and target SP Program status control Segment operation Advance segment jump hold and wait Program operation Program repetitions and program links Wait operation Wait method...

Page 87: ...umidity 10 to 80 Altitude 2 000 m max Weight Approx 120 g Transmission line connection method RS 485 Multidrop Communications RS 485 two wire half duplex Synchronization method Start stop synchronizat...

Page 88: ...V I 003 Communications RS 485 CT1 and CT2 14 15 14 15 EV1 EV2 EV1 EV2 EV3 EV4 EV3 EV4 B A RS 485 B A RS 485 CT2 COM CT1 3 1 2 3 1 2 Models with 1 Relay Output 3 Q 1 2 3 1 Control outputs 1 2 Q 1 2 Mod...

Page 89: ...60 4 1 48 48 Mounting Adapter Accessory Y92F 49 also available for ordering separately Waterproof Packing Accessory Y92S P8 also available for ordering separately E5CC T Recommended panel thickness is...

Page 90: ...d with the Temperature Controller Order the Waterproof Packing separately if it becomes lost or damaged The Waterproof Packing can be used to achieve an IP66 degree of protection Deterioration shrinki...

Page 91: ...Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 18 2 Thru current Io A r m s 1 10 100mA 1 10 100 1 000A 100V Frequency 50 Hz Distortion factor 10 3 1 100 RL...

Page 92: ...or E54 CT3L Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Digital Temperature Controller is 50 A Number of windings 400 2 Winding resistance 8 0 8 Th...

Page 93: ...use the Y92F 45 Adapter To use the USB Serial Conversion Cable to make the settings do so before you mount the Temperature Controller in the panel 4 You cannot use this Adapter together with the Y92F...

Page 94: ...d with the Temperature Controller Order the Mounting Adapter separately if it becomes lost or damaged This Protective Cover is soft type It is able to operate the controller with using this cover Note...

Page 95: ...95 MEMO...

Page 96: ...mm E5AC T Refer to your OMRON website for the most recent information on applicable safety standards Refer to Safety Precautions on page 122 CSA conformance evaluation by UL 4 digit displays Sensor I...

Page 97: ...iliary outputs Power supply voltage Terminal type Input type Options E5EC T 48 96 mm Programmable Type E5AC T 96 96 mm Programmable Type Control output 1 Control output 2 RX Relay output None QX Volta...

Page 98: ...roller Mounting Adapter Note This Mounting Adapter is provided with the Digital Temperature Controller Current Transformers CTs Lead wires are included with these CTs If UL certification is required u...

Page 99: ...rence value Event input Number of inputs 2 4 or 6 depends on model External contact input specifications Contact input ON 1 k max OFF 100 k min Non contact input ON Residual voltage 1 5 V max OFF Leak...

Page 100: ...mperature sensor Sensor specification Pt100 JPt100 K J T E L U N R S B C W PLII 10 to 70 C 60 to 120 C 115 to 165 C 140 to 260 C 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 4...

Page 101: ...ndby sequence A standby sequence is added to the lower limit alarm 3 6 8 Absolute value upper limit The alarm will turn ON if the process value is larger than the alarm value X regardless of the set p...

Page 102: ...t No H185 for information on the operation of the standby sequence 7 Refer to the E5 C T Digital Temperature Controllers Programmable Type User s Manual Cat No H185 for information on the loop burnout...

Page 103: ...ng or Position proportional Close 0 to 9999 s in units of 1 s 0 0 to 999 9 s in units of 0 1 s Position proportional Floating 1 to 9999 s in units of 1 s 0 1 to 999 9 s in units of 0 1 s 4 Derivative...

Page 104: ...SP function Select from ramp SP and target SP Program status control Segment operation Advance segment jump hold and wait Program operation Program repetitions and program links Wait operation Wait me...

Page 105: ...ensation or icing Storage humidity 10 to 80 Altitude 2 000 m max Weight Approx 120 g Transmission line connection method RS 485 Multidrop Communications RS 485 two wire half duplex Synchronization met...

Page 106: ...8 13 14 15 29 30 31 32 33 28 V I EV1 EV2 EV3 EV4 EV5 EV6 CT1 Voltage output for driving SSR 12 VDC 21 mA Relay output 250 VAC 5 A resistive load Linear current output 0 to 20 mA DC 4 to 20 mA DC Load...

Page 107: ...ess M and D Keys simultaneously for at least 1 second to switch between run and reset status E5EC T Front Panel Top View of E5AC T Top panel Setup Tool port Temperature unit Operation indicators Press...

Page 108: ...t the sur rounding temperature does not exceed the allowable operating tem perature specified in the specifications Selections for Control Outputs 1 and 2 QQ QR RR CC PR or CQ If you also specify 019...

Page 109: ...To mount the Controller so that it is waterproof insert the waterproof packing onto the Controller When two or more Controllers are mounted make sure that the sur rounding temperature does not exceed...

Page 110: ...r on the front panel Setup Tool port of the E5EC T E5AC T securely closed To maintain an IP66 degree of protection the Waterproof Packing and the Port Cover for the front panel Setup Tool port must be...

Page 111: ...vs Output Voltage Eo Reference Values E54 CT1 or E54 CT1L Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 18 2 Thru current Io A r m s 1 10 100mA 1 10 100...

Page 112: ...CT3 or E54 CT3L Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Digital Temperature Controller is 50 A Number of windings 400 2 Winding resistance 8 0...

Page 113: ...113 MEMO...

Page 114: ...he S Key 3 Protect Level Calibration Level Manual Control Level Press the O Key for at least 1 s Press the O Key for at least 1 s or the S Key for at least 1 s 1 Used to set the MV manually Used for S...

Page 115: ...set the MV manually Used for SPs and other basic settings and monitoring Press O Key for at least 3 s while a m is displayed 2 Used to set protection for operations Enter the password 1201 while cmov...

Page 116: ...ote SP Input Slope Coefficient Proportional Band Integral Time Derivative Time Dead Band SP Ramp Fall Value Manual Reset Value Hysteresis Heating Hysteresis Cooling Soak Time Wait Band MV at Stop MV a...

Page 117: ...Press the O Key for at least 1 s Advanced Function Setting Level Alarm 3 Type Alarm 3 Hysteresis Transfer Output Type Transfer Output Upper Limit Transfer Output Lower Limit Event Input Assignment 1 E...

Page 118: ...1 olh 100 0 1 oll 0 0 1 aut 1320 1 lba 0 M 1 p 8 0 1 i 233 1 d 40 1 c p 8 0 1 c i 233 PID 1 Proportional Band PID 1 Integral Time PID 1 Derivative Time PID 1 Proportional Band Cooling PID 1 Integral T...

Page 119: ...t Lower Limit Event Input Assignment 1 Close Floating Motor Calibration Travel Time Valve Completely Closed Position vl o 9999 pms 0 sqr off amov 0 Valve Completely Open Position Potentiometer Specifi...

Page 120: ...V Rate of Change Calculation Period Minimum Output ON OFF Band PID Set Automatic Selection Hysteresis pidh p db pvrp hctm ompw pend s u rest sb1n hbu hbl hbh alfa tidu at g at h lcma inf mav Automatic...

Page 121: ...ser s Manual Cat No H174 or the E5 C T Digital Temperature Controllers Programmable Type User s Manual Cat No H185 for information on the controllable range Above 9 999 e333 A D converter error There...

Page 122: ...DC E5DC B check the condition of the Terminal Unit If corroded terminals are used contact failure in the terminals may cause the temperature inside the Digital Temperature Controller to increase possi...

Page 123: ...other equipment that have an inductance component When a noise filter is used at the power supply first check the voltage or current and attach the noise filter as close as possible to the product Al...

Page 124: ...als When you insert the interior body into the rear case confirm that the hooks on the top and bottom are securely engaged with the case 36 Observe the following precautions when you wire the E5 C B A...

Page 125: ...ss installing These devices can cause radio disturbances which adversely affect the performance of the Controller Others 1 Do not Connect or disconnect the Conversion Cable connector repeatedly over a...

Page 126: ...m the terminals up to the panel and temporarily fasten the E5EC E5EC B E5AC E5EC T E5AC T 4 Tighten the two fastening screws on the adapter Alternately tighten the two screws little by little to maint...

Page 127: ...llation Make sure to attach PFP M End Plates to the ends of the Units Mounting to a DIN Track in Connection 1 Remove the connector cover on the side to use for connecting to another terminal unit and...

Page 128: ...ce Tighten the screws to a torque of 0 29 to 0 39 N m 4 On the wired terminal unit remove the connector cover on the side to use for connection to another terminal unit and then connect the units toge...

Page 129: ...no vertical direction for male connector covers For female connector covers 1 Insert the projecting part on the female connector cover into the groove on the terminal unit 2 Press on the female conne...

Page 130: ...he terminal block as shown in the following diagram The Terminal Cover cannot be attached in the opposite direction Attaching the End Cover E5DC E5DC B 1 Install the E5DC E5DC B in a panel 2 Peel off...

Page 131: ...he rear case the rear case may not be waterproof When inserting the Digital Controller do not allow the electronic components to touch the rear case Removing the draw out jig when only one hook is cau...

Page 132: ...Recommended Crimp Terminals with Insulation Sleeves for the E5DC E5GC Controllers with Screwless Clamp Terminal Blocks 1 Connection Method for Screwless Clamp Terminals The same method is used to con...

Page 133: ...insert the wire into the terminal hole until it strikes the terminal block 3 Remove the flat blade screwdriver from the release hole Checking Connections After the insertion pull gently on the wire t...

Page 134: ...lowing flat blade screwdriver The following table shows manufacturers and models as of 2015 Dec OMRON s exclusive purchase model XW4Z 00B is available to order as SZF 0 0 4 x 2 5 manufactured by Phoen...

Page 135: ...or DIN Track Example Mounted to Panel Note Average Operating Temperature Refer to the process temperature of the Unit mounted to a control panel and connected to peripheral devices on condition that...

Page 136: ...MEMO 136...

Page 137: ...TERS Chicago IL USA 847 843 7900 800 556 6766 automation omron com Controllers I O Machine Automation Controllers MAC Motion Controllers Programmable Logic Controllers PLC Temperature Controllers Remo...

Reviews: