![background image](http://html1.mh-extra.com/html/omron/e3x-drt21-s/e3x-drt21-s_user-manual_741345097.webp)
95
E3X-DRT21-S
User’s Manual
Section 4
APP
E
NDIX
Section 4
DeviceNet Device Profile
DeviceNet Device Profile
Device Profile
(*1) The current supplied to Sensors is excluded.
General data
Compatible DeviceNet specifications
Volume - Release 2.0
Volume - Release 2.0
Vendor name
OMRON Corporation
Vendor ID = 47
Device profile name
Communication Adapter
Profile number = 12
Product catalog number
Product revision
1.01
Physical
conformance
data
Network current consumption
24 VDC, 70 mA max. (*1)
Connector type
Open plug
Physical insulation
None
Supported LEDs
Module, Network
MAC ID setting
DIP switch
Default MAC ID
0
Transmission baud rate setting
Automatic tracking
Supported transmission baud rate
125 kbit/s, 250 kbit/s, 500 kbit/s
Communications
data
Predefined master/
slave connection set
Group 2 only server
Dynamic connection
support (UCMM)
None
Explicit message
fragmentation support
Yes