51
E3X-DRT21-S
User’s Manual
Sect
ion 3
Dev
ic
e
Net
Co
m
m
u
n
ic
at
io
n Se
tt
ings
Section 3
Explicit Message Communications
●
Read the detection level/read the detection level on detected (ON)/
read the detection level on undetected (OFF)
These commands read the detection level of the sensor with the unit No. specified with
the Instance ID.
Those data is shown in hexadecimal as a four-digit value (two bytes).
If the data is negative, the 12th bit is 1 (on).
Read Detection level on Detected (ON) and Read Detection level on Undetected (OFF)
can read the detection level only when the display switching settings are peak on
detected and bottom on undetected.
Also, its data range is between F831Hex (complement of 2) and 0FA0Hex.
●
Read detection level + ON/OFF output
It reads the detection level of the sensor with the unit No. specified with the Instance ID.
The data is shown in hexadecimal as a four-digit value (two bytes).
If the data is negative, the 12th bit is 1 (on).
Detection level
Bit
15
Bit
14
Bit
13
Bit
12
Bit
11
Bit
10
Bit
09
Bit
08
Bit
07
Bit
06
Bit
05
Bit
04
Bit
03
Bit
02
Bit
01
Bit
00
0 Fixed
0:
+
/
1:
-
The detection level (000Hex to FA0Hex)
Detection level + ON/
OFF output
Bit
15
Bit
14
Bit
13
Bit
12
Bit
11
Bit
10
Bit
09
Bit
08
Bit
07
Bit
06
Bit
05
Bit
04
Bit
03
Bit
02
Bit
01
Bit
00
*1
*2
0
Fixed
0:
+
/
1:
-
The detection level (000Hex to FA0Hex)
Bit
Description
Data
Bit 14 (*2)
External input data
0: No external input, 1: External input
Bit 15 (*1)
ON/OFF output data
0: OFF, 1: ON