Section 3
Explicit Message Communications
●
Read Power Tuning Target Value Settings
It reads the power tuning target value settings of the sensor with the unit No. specified
with the Instance ID. Its read data is expressed in hexadecimal and its length is two
bytes; the data range is between 0064hex (100) and 0F3Chex (4000).
●
Read Output Settings
It reads the output settings of the sensor with the unit No. specified with the Instance
ID.
●
Read Output Setting Timer Function Settings
It reads the output setting timer function settings of the sensor with the unit No.
specified with the Instance ID.
●
Read Output Setting Timer Time Settings
It reads the output timer time settings of the sensor with the unit No. specified with the
Instance ID.
Its read data is expressed in hexadecimal and its length is two bytes; the data range is
between 0000hex (0) and 1388hex (5000).
When the output setting timer function setting is OFF, [Output Setting Timer Time
Settings] command fails if the command is sent.
Bit
Description
Data
00
Output settings
0: Output for each channel
1: Area output (TW, LDATW, EDATW)
2: Self diagnosis output (TW, LDATW, EDATW)
3: AND output (MDA)
4: OR output (MDA)
5: Difference output (MDA)
6: Rising edge sync output (MDA)
7: Down edge sync output (MDA)
8: Head error output (E2C)
01
02
03
04 to 15
No data
Always 0
Bit
Description
Data
00
Output setting timer
function
0: Timer function disabled
1: OFF-delay timer
2: ON-delay timer
3: One-shot timer
01
02 to 15
No data
Always 0