Explicit Message Communications
■
Write Command List
A list of Explicit Message Write commands is shown below.
[Supported Models]
E3X-DA7-S, E3X-DA9-S: DA7, E3X-DA-S: DA, E3X-MDA: MDA, E3X-DATW-S: TW,
E3X-DARM-S: RM; E3X
E3C-LDA (2 output types): LDATW, E3C-LDA (input type): LDARM; E3C
E2C-EDA (2 output types): EDATW, E2C-EDA (input type): EDARM; E2C
Explicit Messages
Functions
Command
Supported
Model
Class
ID
Instance
ID
Attribute
ID
Write Threshold
Settings
With specifying a Unit No. with the
Instance ID, writes the threshold value.
9C
Unit
Number
11
All models
Write Differentiation
Threshold Value
Settings
With specifying a Unit No. with the
Instance ID, writes the differentiation
mode threshold.
9C
Unit
Number
10
Except DA,
and MDA
Write Difference
Threshold Settings
With specifying a Unit No. with the
Instance ID, writes the threshold value
when the difference outputs.
9C
Unit
Number
12
MDA
Write Operating
Mode Settings
With specifying a Unit No. with the
Instance ID, writes the operating mode.
9C
Unit
Number
20
DA7, TW,
MDA,
LDATW,
EDATW
Write Detection
Mode Settings
With specifying a Unit No. with the
Instance ID, writes the detection mode.
9C
Unit
Number
21
All models
Write Differentiation
Edge Settings
With specifying a Unit No. with the
Instance ID, writes the differentiation
edge.
9C
Unit
Number
22
Except DA,
and MDA
Write Differentiation
Mode
Response Time
With specifying a Unit No. with the
Instance ID, writes the differentiation
mode response time.
9C
Unit
Number
23
Except DA,
and MDA
Write Timer
Function Settings
With specifying a Unit No. with the
Instance ID, writes the timer function.
9C
Unit
Number
24
All models
Write Timer Time
Settings
With specifying a Unit No. with the
Instance ID, writes the timer time.
9C
Unit
Number
25
All models
ON-Delay and OFF-
Delay timerWrite
ON-Delay timer time
Settings
With specifying a Unit No. with the
Instance ID, writes the ON-Delay timer
time.
9C
Unit
Number
F6
DA7
ON-Delay and OFF-
Delay timerWrite
OFF-Delay timer
time Settings
With specifying a Unit No. with the
Instance ID, writes the OFF-Delay timer
time.
9C
Unit
Number
F7
DA7
Write Display
Switching Settings
With specifying a Unit No. with the
Instance ID, writes the display switching
settings.
9C
Unit
Number
26
All models
Write MODE Key
Settings
With specifying a Unit No. with the
Instance ID, writes the MODE key
settings.
9C
Unit
Number
27
All models