![background image](http://html1.mh-extra.com/html/omron/e3x-drt21-s/e3x-drt21-s_user-manual_741345055.webp)
53
E3X-DRT21-S
User’s Manual
Sect
ion 3
Dev
ic
e
Net
Co
m
m
u
n
ic
at
io
n Se
tt
ings
Section 3
Explicit Message Communications
●
Read Detection Function Settings
It reads the operating mode settings of the sensor with the unit No. specified with the
Instance ID.
Note that some models cannot be set to the high speed mode.
●
Read Differentiation Edge Settings
It reads the differentiation edge settings of the sensor with the unit No. specified with
the Instance ID.
●
Read Differentiation Response Speed Settings
It reads the differentiation response speed settings of the sensor with the unit No.
specified with the Instance ID.
●
Read Timer Function Settings
It reads the timer function settings of the sensor with the unit No. specified with the
Instance ID.
Bit
Description
Data
00
Detection mode
0: STAND, 1: HI-RESO,
2: Differentiation, 4: High speed,
6: Tough(DA7)
01
02
03 to 15
No data
Always 0
Bit
Description
Data
00
Operating mode
0: Single-end edge, 1: Double-end edge
01 to 15
No data
Always 0
Bit
Description
Data
00
Differentiation
response time
1: Differentiation response speed setting 1
2: Differentiation response speed setting 2
3: Differentiation response speed setting 3
4: Differentiation response speed setting 4
5: Differentiation response speed setting 5
01
02
03
04 to 15
No data
Always 0
Bit
Description
Data
00
Timer function
0: Timer function disabled
1: OFF-delay timer
2: ON-delay timer
3: One-shot timer
4: ON-delay and OFF-delay timer
01
02 to 15
No data
Always 0