Wiring the SmartStep2 servo option:
The 100W, 200W and 400W SmartStep2 servomotor system will have been supplied with
the R7A-FIB104-RE footprint RFI filter. The R7D-BP0
servomotor amplifier should be
attached to this filter using the supplied M4 screws.
1. Connect a 230VAC supply to the filter, as shown in the diagram above, ensuring
that an earth connection is made to the M4 stud behind the terminal block.
2. Connect the output power connector from the filter into ‘CNA’ of the servo amplifier.
Attach the flying earth cable eyelet to one of the two earthing screws to the left side
of this connector.
L N E
230VAC
MAINS
SUPPLY
filter side
view