46
Error Detection
Section 5
Error Detection
When an error occurs with resolver input or at the Cam Positioner Unit, the
content of the error is output to the Data Setting Console and to an input relay
to notify the user.
Errors, Causes and
Corrections
Status at time of error:
Refers to the operation status and the cam output status when the error
occurs.
O: Operation or cam output continues.
X: Operation or cam output stops.
Display
Error
Operation
mode
Status at time
of error
Probable cause
Possible correction
PRG
RUN
Oper-
ating
Cam
output
Memory error
❍
❍
×
×
There is an error in the
EEPROM of the Cam Posi-
tioner Unit.
Clear the error (see
page 48).
Replace the Unit.
Communica-
tion error
❍
❍
❍
❍
There is an error in the com-
munications between the
Cam Positioner Unit and the
Data Setting Console.
Clear the error (see
page 48).
Replace the connection
cable.
Replace the Unit.
Power failure
error
❍
❍
×
×
Power was interrupted during
data setting or origin adjust-
ment.
Clear the error (see
page 48), and then make
the settings again.
Bank change
error
×
❍
×
×
The bank number data in
word n + 1 is not set from 00
to 08
The cam setting data is cor-
rupted.
Clear the error (see
page 48), and then set
the bank number cor-
rectly.