![background image](http://html1.mh-extra.com/html/omron/a2w-r-wc1-series/a2w-r-wc1-series_user-manual_744284068.webp)
5 Registration in the ID Mode
5 - 6
Wireless Pushbutton Switch User’s Manual (A265)
Delete All the Slave Buttons Registered in the Specific Output Together
Example: When the Slave button # 1 and # 2 are assigned to the output No. 1 of the Master Unit, the
output No. 1 is deleted
Delete operation is performed only on the Master Unit side.
Operation Procedure Flowchart
Delete all Slave Buttons Together
Output setting of Master Unit
<After deletion>
Slave buttons assigned to the Master Unit
The Slave buttons #1 and #2 assigned
to the output No. 1 are deleted.
<Before Deletion>
# 1
# 2
# 3
# 4
Output setting of Master Unit
# 2
# 3
# 4
1. Set the mode
settings switch
to "ID".
2. Set the output
settings switch
to "DEL".
3. All output
LEDs will turn
yellow.
4. Push the reset
switch until
the RCV LED
lights green
for 3 seconds.
Delete start
< Master Unit>
5. Delete complete
Summary of Contents for A2W-R**-WC1 Series
Page 14: ...Revision History 12 Wireless Pushbutton Switch User s Manual A265...
Page 40: ...2 Overview 2 20 Wireless Pushbutton Switch User s Manual A265...
Page 74: ...5 Registration in the ID Mode 5 12 Wireless Pushbutton Switch User s Manual A265...
Page 90: ...8 Trouble Shooting 8 8 Wireless Pushbutton Switch User s Manual A265...
Page 94: ...Appendix A 4 Wireless Pushbutton Switch User s Manual A265...
Page 95: ......