2 - 13
2 Overview
Wireless Pushbutton Switch User’s Manual (A265)
2-4
Nom
enclat
u
re an
d F
unc
tion
s
2
2-
4-1 Ma
ster
Unit
Mode Settings Switch
Set the operation mode of the Master Unit.
Factory setting: ID
Output Settings Switch
Register or delete the Slave button ID
*1
for each output number of the Master Unit.
Factory setting: 1
*1. This is the identification number of the Slave button for wireless communications.
Setting Switches
Operation
mode
Function
RUN
Communications mode: Normal communications
TEST
Test mode: Installation tests such as reception strength measurement, etc.
* There is no output from the output terminal.
ID
ID mode: Register or delete Slave buttons
Number
Enabled mode
Other settings requirements
Function
1 to 8
ID
Continuous data reception
within a fixed period from the
Slave button to be registered
Register the ID of the target Slave button
to be registered in the specified output
number
Press the Reset switch (ON)
Delete IDs of all Slave buttons registered
in the specified output number
DEL
Continuous data reception
within a fixed period from the
Slave button for which the regis-
tration is to be deleted
Delete the ID of the Slave button to be
deleted from the registration list
Press the Reset switch (ON)
Delete all IDs from the registration list
ERR CLR ERR LED lit red
+
RCV LED lit yellow
Press the Reset switch (ON)
Execute the software reset of the Master
Unit
Summary of Contents for A2W-R**-WC1 Series
Page 14: ...Revision History 12 Wireless Pushbutton Switch User s Manual A265...
Page 40: ...2 Overview 2 20 Wireless Pushbutton Switch User s Manual A265...
Page 74: ...5 Registration in the ID Mode 5 12 Wireless Pushbutton Switch User s Manual A265...
Page 90: ...8 Trouble Shooting 8 8 Wireless Pushbutton Switch User s Manual A265...
Page 94: ...Appendix A 4 Wireless Pushbutton Switch User s Manual A265...
Page 95: ......