2 - 11
2 Overview
Wireless Pushbutton Switch User’s Manual (A265)
2-4
Nom
enclat
u
re an
d F
unc
tion
s
2
2-
4-1 Ma
ster
Unit
---
Reset switch
• Delete the Slave button registration information corresponding to the output
settings switch.
• By pressing the output settings switch in the "ERR CLR" state when an error
output is generated, error output will be reset.
• When the power is turned ON in the pressed state, it is reset to the factory
setting.
---
Output settings
switch
Used to register or delete the ID of the Slave button to or from the output of the
Master Unit.
Also used to reset the error output without using the error clear terminal.
---
Mode settings switch
Set the operation mode of the Master Unit to ID mode, TEST mode, and RUN
mode.
---
Power supply LED
Lit green when the power is ON.
---
Error LED
Lit red when there is a possibility that abnormality occurs in the master unit
and it will not output correctly according to the Slave button operation.
---
Received field
strength LED
• RUN mode, or TEST mode
It lights according to the received electric field strength of the received data.
Lit green: Received field strength is "Strong"
Lit yellow: Received field strength is "Weak"
• ID registration mode
Lit green when registration or deletion is success.
Flashing green when registration or deletion is failure.
• When error output occurs
Lit green when the Master Unit setting data error is detected.
Lit yellow when there is a possibility that the Master Unit will not output
properly according to the Slave button operation.
---
Output LED
• RUN mode
When outputting to the output terminal, the corresponding output LED lit yel-
low.
• TEST mode
It does not output to the output terminal, and the corresponding output LED
lit yellow.
• ID mode
The output LED corresponding to the output setting switch lit yellow.
Display
LED
name
Color
Enabled
mode
Status
Meaning
PWR
Green
Always
enabled
Lit
During Power Supply
Not lit
No power supplied
RCV
Green
or Yel-
low
RUN/TEST
Lit/Not lit
Received field strength monitor:
Lit green: Received field strength is "Strong" (lit up for 500 msec)
Lit yellow: Received field strength is "Weak" (lit up for 500 msec)
Not lit:
No received
ID
Lit/Not
lit/Flashing
ID registration:
Lit green:
ID registration successful (lit up for 3 s)
Not lit:
Data for ID registration not received
Flashing green: ID registration failed (flashes for 3 s after every 250 ms)
Delete ID:
Lit green:
ID deletion successful (lit up for 3 s)
Not lit:
Data for ID deletion not received
Flashing green: ID deletion failed (flashes for 3 s after every 250 ms)
Enabled
only when
ERR LED is
lit
Lit/Not lit
Lit green:
Error in Master Unit setting data
Lit yellow:
Error in the most important function (wireless received,
registration/verification, or output)
All not lit:
Error in CPU initialization process during startup
Number
Terminal
name
Name
Function
Q
R
S
T
U
V
W
Summary of Contents for A2W-R**-WC1 Series
Page 14: ...Revision History 12 Wireless Pushbutton Switch User s Manual A265...
Page 40: ...2 Overview 2 20 Wireless Pushbutton Switch User s Manual A265...
Page 74: ...5 Registration in the ID Mode 5 12 Wireless Pushbutton Switch User s Manual A265...
Page 90: ...8 Trouble Shooting 8 8 Wireless Pushbutton Switch User s Manual A265...
Page 94: ...Appendix A 4 Wireless Pushbutton Switch User s Manual A265...