Connection manual of XDesignerPlus external devices

 

7 / 12 

4.2 Setting details of TOP main menu 

- When hearing the sound while resetting the power, touch 1 upper point on LCD to move to“TOP   
management main” screen.. 
- Set the driver interface settings of TOP according to the contents; 

Step1

 → 

Step2

(You can change the settings in 

Step2.

if you click on “TOP COM 2/1 settings” in 

Step 1.

.) 

 
 
 
 

S

tep 

1

.

 [ PLC Setup ] – Set the driver interface. 

PLC Setup 
PLC station number : 00 

Communication    interface 

Time-out : 1000 [mSec] 

settings 

Delay time before transmission : 0 [mSec] 

 

TOP COM 2/1 : RS – 232C , 9600 , 7 , 2 , EVEN 

 

TOP COM 2/1 settings    Communication    check 

 

Step 1–Reference.

 

Details 

Contents 

PLC station number. 
[0~65535] 

It is the station number of the other device. Select between [ 0 – 65535 ]. 

Time-out [ x1 mSec ] 

Set the TOP’s wait time for response from external devices at [ 0 – 5000 ] x 1 mSec. 

Delay time before 
transmission [ x1 mSec ] 

Set the TOP’s wait time between receiving the response from external devices – transmitting 
the next command request at [0 - 5000] x 1 mSec. 

TOP COM 2/1 

It is the interface settings of TOP for external devices. 

 
 

S

tep 

2

.

 [ PLC Setup ] >[ TOP COM2/COM1 settings ] 

 Set the serial parameters of the relevant port.

 

port settings 

* Serial communication   

COM 1 port 

  + COM-1 Port 

communication    interface 

    - Parity bit : 9600 [BPS] 

settings 

    - Data bit : 7 [BIT] 

 

    - Stop bit: 2 [BIT] 

 

    - Parity bit: EVEN [BIT] 

 

    - Signal level : RS – 232C 

 

  + COM-2 Port 

COM 2 port 

    - Parity bit : 9600 [BPS] 

communication    interface 

    - Data bit : 7 [BIT] 

settings 

    - Stop bit: 2 [BIT] 

 

    - Parity bit: EVEN [BIT] 

 

    - Signal level : RS – 232C 

 

Step 2-Reference. 

Details 

Contents 

Parity bit 

Select a serial communication speed between TOP –    External devices 

Data bit 

Select a serial communication data bit between TOP –    External devices.   

Stop bit 

Select a serial communication stop bit between TOP –    External devices.   

Parity bit 

Select a method of checking serial communication parity bit between TOP –    External devices.   

Signal level 

Select a serial communication method between TOP –    External devices. 

 

 

Summary of Contents for 3F88L-160

Page 1: ...l devices Page 3 Select a TOP model and external devices 3 Example of system settings Page 4 Explains an example of settings for communication interface between the devices and the relevant external t...

Page 2: ...and OMRON Corporation CAM Positioner Series 3F88L 160 162 is as follows Series CPU Link I F Communicati on method Systemsettings Cable CAM Positioner 3F88L 160 162 Communication Port on CPU Unit RS 23...

Page 3: ...S version specified in the table below according to TOP series Series Version name XTOP HTOP V4 0 Name Select the model name of TOP product External device Vendor Select the vendor of external devices...

Page 4: ...BPS 9600 User settings Serial data bit Bit 7 User settings Serial stop bit Bit 2 User settings Serial parity bit Bit EVEN User settings 1 XDesignerPlus settings After setting the below details in Proj...

Page 5: ...rnal devices as shown below Please refer to the User s Manual of external devices for more detailed settings 1 Set Function No b Parameter No 6 as 1 Set the Parity bit 9600 bps factory setting 2 Switc...

Page 6: ...erface settings Details Contents Signal level Select a serial communication method between TOP External devices COM1 supplies RS 232C only Baud rate Select a serial communication speed between TOP Ext...

Page 7: ...1 mSec Set the TOP s wait time between receiving the response from external devices transmitting the next command request at 0 5000 x 1 mSec TOP COM 2 1 It is the interface settings of TOP for externa...

Page 8: ...It is an error in the settings of a TOP external device and cable reference communication check sheet Communication check sheet Please check the settings shown in the sheet below if there is an error...

Page 9: ...s seen at the connection area of cable connection connector B XTOP COM 2 port 15pin XTOP COM2 Cable connection PLC PIN arrangement Note1 Signal name Pin number Pin number Signal name PIN arrangement N...

Page 10: ...rigin compensation value 4 digit BCD from 0000 to 0359 0719 Address 0002 Leftmost byte Address 0003 Rightmost byte X 0004 0005 Backlash Compensation value Backlash compensation value 4 digit BCD from...

Page 11: ...s for bank1 Address 0070 to 0073 Bank 7 cam data protect setting Address 0074 to 0077 Bank 7 one direction function setting Address 0078 to 007B Bank 7 rotation direction setting X 0080 to 008B Bank8...

Page 12: ...for Bank 8 Same as for Bank 1 X Note1 The 8 digits of data can be read when the P0000 address uses 32BIT Controller Status Read RUN PRGM SET S Address Name Detailed information 32 BIT available Status...

Reviews: