Connection manual of XDesignerPlus external devices

 

12 / 12 

Address 

Name 

Detailed information 

32 BIT available 

6000 

to 

6BCF 

Cam  Programs 

for Bank 6 

Same as for Bank 1 

7000 

to 

7BCF 

Cam  Programs 

for Bank 7 

Same as for Bank 1 

8000 

to 

8BCF 

Cam  Programs 

for Bank 8 

Same as for Bank 1 

*Note1)The 8 digits of data can be read when the P0000 address uses 32BIT. 
 
- Controller Status Read (RUN, PRGM, SET) : S 

Address 

Name 

Detailed information 

32 BIT available 

Status Read 

bit 0 : Executing Status ( 0 – When an error occurs in Run mode or PRGM or 
            SET mode is entered 

                                          1 – When there is no error in RUN mode) 
bit 6 : (1 - When the Communications function is being executed to change 
            the operating state) 
bit 7 : (1 – When an error occurs) 

 

Summary of Contents for 3F88L-160

Page 1: ...l devices Page 3 Select a TOP model and external devices 3 Example of system settings Page 4 Explains an example of settings for communication interface between the devices and the relevant external t...

Page 2: ...and OMRON Corporation CAM Positioner Series 3F88L 160 162 is as follows Series CPU Link I F Communicati on method Systemsettings Cable CAM Positioner 3F88L 160 162 Communication Port on CPU Unit RS 23...

Page 3: ...S version specified in the table below according to TOP series Series Version name XTOP HTOP V4 0 Name Select the model name of TOP product External device Vendor Select the vendor of external devices...

Page 4: ...BPS 9600 User settings Serial data bit Bit 7 User settings Serial stop bit Bit 2 User settings Serial parity bit Bit EVEN User settings 1 XDesignerPlus settings After setting the below details in Proj...

Page 5: ...rnal devices as shown below Please refer to the User s Manual of external devices for more detailed settings 1 Set Function No b Parameter No 6 as 1 Set the Parity bit 9600 bps factory setting 2 Switc...

Page 6: ...erface settings Details Contents Signal level Select a serial communication method between TOP External devices COM1 supplies RS 232C only Baud rate Select a serial communication speed between TOP Ext...

Page 7: ...1 mSec Set the TOP s wait time between receiving the response from external devices transmitting the next command request at 0 5000 x 1 mSec TOP COM 2 1 It is the interface settings of TOP for externa...

Page 8: ...It is an error in the settings of a TOP external device and cable reference communication check sheet Communication check sheet Please check the settings shown in the sheet below if there is an error...

Page 9: ...s seen at the connection area of cable connection connector B XTOP COM 2 port 15pin XTOP COM2 Cable connection PLC PIN arrangement Note1 Signal name Pin number Pin number Signal name PIN arrangement N...

Page 10: ...rigin compensation value 4 digit BCD from 0000 to 0359 0719 Address 0002 Leftmost byte Address 0003 Rightmost byte X 0004 0005 Backlash Compensation value Backlash compensation value 4 digit BCD from...

Page 11: ...s for bank1 Address 0070 to 0073 Bank 7 cam data protect setting Address 0074 to 0077 Bank 7 one direction function setting Address 0078 to 007B Bank 7 rotation direction setting X 0080 to 008B Bank8...

Page 12: ...for Bank 8 Same as for Bank 1 X Note1 The 8 digits of data can be read when the P0000 address uses 32BIT Controller Status Read RUN PRGM SET S Address Name Detailed information 32 BIT available Status...