background image

 

 

Connection manual of XDesignerPlus external devices

 

11 / 12 

Address 

Name 

Detailed information 

32 BIT available 

0020 

to 

002B 

Bank2   

Same as for bank1 

Address 0020 to 0023 : Bank 2 cam data protect setting 

Address 0024 to 0027 : Bank 2 one-direction function setting 

Address 0028 to 002B : Bank 2 rotation direction setting 

0030 

to 

003B 

Bank3   

Same as for bank1 

Address 0030 to 0033 : Bank 3 cam data protect setting 

Address 0034 to 0037 : Bank 3 one-direction function setting 

Address 0038 to 003B : Bank 3 rotation direction setting 

0040 

to 

004B 

Bank4   

Same as for bank1 

Address 0040 to 0043 : Bank 4 cam data protect setting 

Address 0044 to 0047 : Bank 4 one-direction function setting 

Address 0048 to 004B : Bank 4 rotation direction setting 

0050 

to 

005B 

Bank5   

Same as for bank1 

Address 0050 to 0053 : Bank 5 cam data protect setting 

Address 0054 to 0057 : Bank 5 one-direction function setting 

Address 0058 to 005B : Bank 5 rotation direction setting 

0060 

to 

006B 

Bank6   

Same as for bank1 

Address 0060 to 0063 : Bank 6 cam data protect setting 

Address 0064 to 0067 : Bank 6 one-direction function setting 

Address 0068 to 006B : Bank 6 rotation direction setting 

0070 

to 

007B 

Bank7   

Same as for bank1 

Address 0070 to 0073 : Bank 7 cam data protect setting 

Address 0074 to 0077 : Bank 7 one-direction function setting 

Address 0078 to 007B : Bank 7 rotation direction setting 

0080 

to 

008B 

Bank8   

Same as for bank1 

Address 0080 to 0083 : Bank 8 cam data protect setting 

Address 0084 to 0087 : Bank 8 one-direction function setting 

Address 0088 to 008B : Bank 8 rotation direction setting 

0100 

Clear Command 

Program Clear, Parameter Clear, and Parameter Update 

1000 

to 

12CF 

Cam  Programs 

for  Cams1  to  8 

of Bank 1 

Program status 

0 : Output OFF / 1 : Output ON 

Address 1000 : Cam 1~8 angle 0 state 

▪▪▪

  Address 12CF : Cam 1~8 angle 719 state 

1300 

to 

15CF 

Cam  Programs 

for Cams9 to 16 

of Bank 1 

Program status 

0 : Output OFF / 1 : Output ON 

Address 1300 : Cam 9~16 angle 0 state 

▪▪▪

  Address 15CF : Cam 9~16 angle 719 state 

1600 

to 

18CF 

Cam  Programs 

for  Cams17  to 

24 of Bank 1 

Program status 

0 : Output OFF / 1 : Output ON 

Address 1600 : Cam 17~24 angle 0 state 

▪▪▪

  Address 18CF : Cam 17~24 angle 719 state 

1900 

to 

1BCF 

Cam  Programs 

for  Cams25  to 

32 of Bank 1 

Program status 

0 : Output OFF / 1 : Output ON 

Address 1900 : Cam 25~32 angle 0 state 

▪▪▪

  Address 1BCF : Cam 25~32 angle 719 state 

2000 

to 

2BCF 

Cam  Programs 

for Bank 2 

Same as for Bank 1 

3000 

to 

3BCF 

Cam  Programs 

for Bank 3 

Same as for Bank 1 

4000 

to 

4BCF 

Cam  Programs 

for Bank 4 

Same as for Bank 1 

500 

to 

5BCF 

Cam  Programs 

for Bank 5 

Same as for Bank 1 

Summary of Contents for 3F88L-160

Page 1: ...l devices Page 3 Select a TOP model and external devices 3 Example of system settings Page 4 Explains an example of settings for communication interface between the devices and the relevant external t...

Page 2: ...and OMRON Corporation CAM Positioner Series 3F88L 160 162 is as follows Series CPU Link I F Communicati on method Systemsettings Cable CAM Positioner 3F88L 160 162 Communication Port on CPU Unit RS 23...

Page 3: ...S version specified in the table below according to TOP series Series Version name XTOP HTOP V4 0 Name Select the model name of TOP product External device Vendor Select the vendor of external devices...

Page 4: ...BPS 9600 User settings Serial data bit Bit 7 User settings Serial stop bit Bit 2 User settings Serial parity bit Bit EVEN User settings 1 XDesignerPlus settings After setting the below details in Proj...

Page 5: ...rnal devices as shown below Please refer to the User s Manual of external devices for more detailed settings 1 Set Function No b Parameter No 6 as 1 Set the Parity bit 9600 bps factory setting 2 Switc...

Page 6: ...erface settings Details Contents Signal level Select a serial communication method between TOP External devices COM1 supplies RS 232C only Baud rate Select a serial communication speed between TOP Ext...

Page 7: ...1 mSec Set the TOP s wait time between receiving the response from external devices transmitting the next command request at 0 5000 x 1 mSec TOP COM 2 1 It is the interface settings of TOP for externa...

Page 8: ...It is an error in the settings of a TOP external device and cable reference communication check sheet Communication check sheet Please check the settings shown in the sheet below if there is an error...

Page 9: ...s seen at the connection area of cable connection connector B XTOP COM 2 port 15pin XTOP COM2 Cable connection PLC PIN arrangement Note1 Signal name Pin number Pin number Signal name PIN arrangement N...

Page 10: ...rigin compensation value 4 digit BCD from 0000 to 0359 0719 Address 0002 Leftmost byte Address 0003 Rightmost byte X 0004 0005 Backlash Compensation value Backlash compensation value 4 digit BCD from...

Page 11: ...s for bank1 Address 0070 to 0073 Bank 7 cam data protect setting Address 0074 to 0077 Bank 7 one direction function setting Address 0078 to 007B Bank 7 rotation direction setting X 0080 to 008B Bank8...

Page 12: ...for Bank 8 Same as for Bank 1 X Note1 The 8 digits of data can be read when the P0000 address uses 32BIT Controller Status Read RUN PRGM SET S Address Name Detailed information 32 BIT available Status...