Table 2-1

mm

(in=mm/25.4)

The outdoor unit should be installed in the location that meets
 the following requiements:

Fig 4.1

S

Fig 4.2

4.2   Figure of body size

4.1   Installation Place

4    OUTDOOR UNIT INSTALLATION

NOTE

NOTE

All the figures in this manual are for explanation purpose only. 
They  may  be  slightly  different  from  the  air  conditioner  you 
purchased.The actual uint shall prevail.

S

tro

n

g w

in

d

A

7

There is enough room for installation and maintenance.
The air outlet and the air inlet are not impeded, and can not be 
reached by strong wind.
It must be a dry and well ventilating place.
The support is flat and horizontal and can stand the weight of 
the outdoor unit. And will no additional noise or vibration.
Your neighborhood will not feel uncomfortable with the noise or 
expelled air.
It is easy to install the connecting pipes or cables.
Determine the air outlet direction where the discharged air is not 
blocked.
There is no danger of fire due to leakage of inflammable gas.
The piping length between the outdoor unit and the indoor unit 
may not exceed the allowable piping length.
In the case that the installation place is exposed to strong wind 
such  as  a  seaside,  make  sure  the  fan  operating  properly  by 
putting  the  unit  lengthwise  along  the  wall  or  using  a  dust 
shield.(Refer to Fig 4.1)
If possible, do not install the unit where it is exposed to direct 
sunlight. 
If necessary, install a blind that does  not interfere with the air 
flow.
Select  the  position  where  it  will not be  subject  to snow  drifts, 
accumulation of leaves or other seasonal debris. If unavoidable, 
please cover it with a shelter.
Locate the outdoor unit as close to the indoor unit as possible.
If possible, please remove the obstacles nearby to prevent the 
performance from being impeded by too little of air circulation.
The minimum distance between the outdoor unit and obstacles 
described in the installation chart does not mean that the same 
is applicable to the  situation of an airtight room. Leave open two 
of the three directions (M,N,P) 

Model

53

71/90

105/140

160

A

795

910

900

1040

B

514

663

590

656

C

340

403

390

463

D

365

427

440

523

E

287

345

360

410

F

330

390

406

452

H

555

712

840

865

Remark

Fig.4.2

Fig.4.2

Fig.4.3

Fig.4.3

Fig 4.3

Summary of Contents for OTEC IECS-D Series

Page 1: ......

Page 2: ...sconnection device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the nat...

Page 3: ...requirement 18 Vacuum pump Charge hose R410A special requirement 19 Torque wrench 20 Copper pipe gauge adjusting projection margin 21 Vacuum pump adapter Required tools for installation work 1 Philip...

Page 4: ...ry if the location is not strong enough Carry out the specified installation works to prevent strong winds or earthquakes Improper installation may cause the unit to drop leading to accidents Before w...

Page 5: ...ling when necessary b Adjust the position of the unit and make sure that the gap with the ceiling is evenly spaced on all four sides of the unit and the base of the unit is 10 12 mm into the base of t...

Page 6: ...therwise it may cause water to leak Calibrate the levelness of the IDU using a spirit level or polyethylene tube filled with water The IDU is equipped with a built in drain pump and float switch Do no...

Page 7: ...ook Drainage pan hook Hook screw Phillips screwdriver Swing motor Foam at panel side Unit Ceiling Panel Panel bubble 1 Air outlet Air deflector Panel bubble 2 4 6 mm The plastic cover plate protruding...

Page 8: ...outdoor unit and the indoor unit may not exceed the allowable piping length In the case that the installation place is exposed to strong wind such as a seaside make sure the fan operating properly by...

Page 9: ...from becoming loose When the outlet of the water discharge pipe is higher than the pipe connection for water suction try to keep the water discharge pipe as vertical as possible and the water outlet c...

Page 10: ...nical surface of the connecting nut the refrigerant oil used must be compatible with the refrigerant of this model and screw it 3 to 4 turns with your hand to tighten it as shown in the Fig 3 9 When c...

Page 11: ...ge Refer to the following table to determine the tightening torque 1 Bend the pipe or drill a hole in the wall as needed The cross sectional area of the pipe bending deformation must not exceed 1 3 of...

Page 12: ...e or valve No power cable is attached to this equipment The user can select the power cable by reference to the stipulated power supply specifications No joint of wires is allowed Upon completion of w...

Page 13: ...ng issues before trial operation and the box for the confirmed items Perform the trial run only after the outdoor unit has been powered on for over 12 hours Check that all valves are opened before tri...

Page 14: ......

Reviews: