1. PRECAUTIONS

CAUTION

CONTENTS

PAGE

PRECAUTIONS......................................................................................1

OVERVIEW............................................................................................2

INSTALLATION......................................................................................3

OUTDOOR UNIT INSTALLATION............................................................7

WATER DISCHARGE PIPING LAYOUT....................................................8

ELECTRIC CONNECTION.......................................................................11

ELECTRIC WIRE DIAGRAM...................................................................12

TRIAL RUN...........................................................................................12

Ensure that all Local, National and International regulations 
are satisfied.
Read this ”PRECAUTIONS ” carefully before Installation. 
The precautions described below include the important 
items regarding safety. Observe them without fail.
After the installation work, perform a trial operation to check
for any problem.
Follow the Owner’s Manual to explain how to use and 
maintain the unit to the customer.
Turn off the main power supply switch (or breaker) before 
maintenance the unit .
Ask the customer that the Installation Manual and the Owner’s
 Manual should be kept together .

New Refrigerant Air Conditioner Installation

CAUTION

Do not connect the Appliance from Main Power Supply.

WARNING

THIS AIR CONDITIONER ADOPTS THE NEW HFC 
REFRIGERANT(R410A)WHICH DOES NOT DESTROY OZONE
LAYER.

The characteristics of  R410A refrigerant are; Hydrophilic, oxid-
izing membrane or oil, and its pressure is approx.1.6 times high-
er than that of refrigerant R22.Accompanied with the new refrig-
erant, refrigerating oil has also been changed ,Therefore, during
 installation work, be sure that water, dust, former refrigerant, or
 refrigerating oil does not enter the refrigerating cycle.
To prevent charging an incorrect refrigerant and refrigerating oil, 
the sizes of connecting sections of charging port of the main 
unit and installation tools are charged from those for the 
conventional refrigerant.

Accordingly the exclusive tools are required for the new 
refrigerant (R410A):
For connecting pipes, use new and clean piping designed for 
R410A,and please care so that water or dust does not enter. 
Moreover, do not use the existing piping because there are 
problems with pressure-resistance force and impurity in it.

This unit  must be connected to the main power supply by 
means of a switch with a contact separation of at least 3 mm.
The installation fuse must be used for the power supply line of 
 this conditioner.

If the supply cord is damaged, it must be replaced by the 
manufacturer or its service agent or a similarly qualified person 
in order to avoid a hazard.
An all-pole disconnection switch having a contact separation of
 at least 3mm in all poles should be connected in fixed wiring.
The appliance shall be installed in accordance with national 
wiring regulations.
The temperature of refrigerant circuit will be high, please keep 
the interconnection cable away from the copper tube.
An all-pole disconnection device which has at least 3mm 
separation distance in all pole and a residual current 
device(RCD) with the rating of above 10mA shall be incorporated 
in the fixed wiring according to the national rule.
The power cord type designation is H05RN-R/H07RN-F or above.
Ask an authorized dealer or qualified installation professional to
install/maintain the air conditioner.

Inappropriate installation may result in water leakage,electric shock
or fire.

Turn off the main power supply switch or breaker before 
attempting any electrical work.

Make sure all power switches are off.Failure to do so may cause 
electric shock.

Connect the connecting cable correctly.

If the connecting cable is connected in a wrong way, electric parts 
may be damaged.

When moving the air conditioner for the installation into another
 place, be very careful not to enter any gaseous matter other
 than the specified refrigerant into the refrigeration cycle.

If air or any other has is mixed in refrigerant, the gas pressure in the 
refrigeration cycle becomes abnormally high and it may resultingly 
causes pipe burst and injuries on persons.

Do not modify this unit by removing any of the safety guards or
by by-passing any of the safety interlock switches.
Exposure of unit to water or other moisture before installation 
may cause a short-circuit of electrical parts.

Do not store it in a wet basement or expose to rain or water.

After unpacking the unit, examine it carefully if there are 
possible damage.
Do not install in a place that might increase the vibration of the 
unit.
To avoid personal injury (with sharp edges), be careful when 
handling parts.
Perform installation work properly according to the Installation 
Manual.

Inappropriate installation may result in water leakage, electric shock 
or fire.

When the air conditioner is installed in a small room, provide 
appropriate measures to ensure that the concentration of 
refrigerant leakage occur in the room does not exceed the 
critical level.
Install the air conditioner securely in a location where the base 
can sustain the weight adequately.
Perform the specified installation work to guard against an 
earthquake.

If the air conditioner is not installed appropriately, accidents may 
occur due to the falling unit.

If refrigerant gas has leaked during the installation work, 
ventilate the room immediately.

If the leaked refrigerant gas comes in contact with fire, noxious gas 
may generate.

After the installation work, confirm that refrigerant gas doer not 
leak.

If  refeigerant gas leaks into the room and flows near a fire source, 
such as a cooking range, noxious gas might generate.

Electrical work must be performed by a qualified electrician in 
accordance with the Installation Manual. Make sure the air 
conditioner uses an exclusive power supply. 

Summary of Contents for OTEC IECS-D Series

Page 1: ......

Page 2: ...sconnection device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the nat...

Page 3: ...requirement 18 Vacuum pump Charge hose R410A special requirement 19 Torque wrench 20 Copper pipe gauge adjusting projection margin 21 Vacuum pump adapter Required tools for installation work 1 Philip...

Page 4: ...ry if the location is not strong enough Carry out the specified installation works to prevent strong winds or earthquakes Improper installation may cause the unit to drop leading to accidents Before w...

Page 5: ...ling when necessary b Adjust the position of the unit and make sure that the gap with the ceiling is evenly spaced on all four sides of the unit and the base of the unit is 10 12 mm into the base of t...

Page 6: ...therwise it may cause water to leak Calibrate the levelness of the IDU using a spirit level or polyethylene tube filled with water The IDU is equipped with a built in drain pump and float switch Do no...

Page 7: ...ook Drainage pan hook Hook screw Phillips screwdriver Swing motor Foam at panel side Unit Ceiling Panel Panel bubble 1 Air outlet Air deflector Panel bubble 2 4 6 mm The plastic cover plate protruding...

Page 8: ...outdoor unit and the indoor unit may not exceed the allowable piping length In the case that the installation place is exposed to strong wind such as a seaside make sure the fan operating properly by...

Page 9: ...from becoming loose When the outlet of the water discharge pipe is higher than the pipe connection for water suction try to keep the water discharge pipe as vertical as possible and the water outlet c...

Page 10: ...nical surface of the connecting nut the refrigerant oil used must be compatible with the refrigerant of this model and screw it 3 to 4 turns with your hand to tighten it as shown in the Fig 3 9 When c...

Page 11: ...ge Refer to the following table to determine the tightening torque 1 Bend the pipe or drill a hole in the wall as needed The cross sectional area of the pipe bending deformation must not exceed 1 3 of...

Page 12: ...e or valve No power cable is attached to this equipment The user can select the power cable by reference to the stipulated power supply specifications No joint of wires is allowed Upon completion of w...

Page 13: ...ng issues before trial operation and the box for the confirmed items Perform the trial run only after the outdoor unit has been powered on for over 12 hours Check that all valves are opened before tri...