![background image](http://html2.mh-extra.com/html/omega/otec-iecs-d-series/otec-iecs-d-series_installation-manual_3955413003.webp)
2
Wired controller is standard.
The air conditioner is delivered from the factory without
connecting pipes.
All the figures in the manual explain only the general
appearance and dimensions of the unit. The air conditioner
you purchased may not be completely consistent with the
appearance and functions listed in the figures. Please refer to
the actual product.
CAUTION
2.1 Accessories
2.2 Locally Purchased Accessories
An insufficient power supply capacity or inappropriate installation
may cause fire.
Use the specified cables for wiring connect the terminals
securely fix. To prevent external forces applied to the
terminals from affecting the terminals.
Be sure to provide grounding.
Do not connect ground wires to gas pipes, water pipes, lightning
rods or ground wires for telephone cables.
Conform to the regulations of the local electric company when
wiring the power supply.
Inappropriate grounding may cause electric shock.
Do not install the air conditioner in a location subject to a risk
of exposure to a combustible gas.
If a combustible gas leaks, and stays around the unit, a fire may
occur.
6) Reamer
7) Gas leak detector
8) Tape measure
9) Thermometer
10) Mega-tester
11) Electro circuit tester
12) Hexagonal wrench
13) Flare tool
14) Pipe bender
15) Level vial
16) Metal saw
17) Gauge manifold (Charge hose:R410A special requirement)
18) Vacuum pump (Charge hose:R410A special requirement)
19) Torque wrench
20) Copper pipe gauge adjusting projection margin
21) Vacuum pump adapter
Required tools for installation work
1) Philips screw driver
2) Hole core drill(65mm)
3) Spanner
4) Pipe cutter
5) Knife
2. OVERVIEW
6.4×0.8
53
Water
discharge
pipe PVC
Insulation
casing
Model Piping Liquid side Gas side
Remarks
12.7×0.8
6.4×0.8
71
15.9×1.0
9.5×0.8
90/105
15.9×1.0
(Unit: mm)
Copper pipe
This is used
as the IDU’s
drain pipe.
The length is
determined
according to
actual
needs.
It is used to connect
the IDU and ODU
refrigerant systems. A
soft copper tube (T2M)
is recommended. The
length is determined
according to actual
needs.
The inner diameter
should match the
corresponding
copper tube and
rigid polyethylene
plastic tube. The
thickness is usually
10mm (or above). If
the pipe is used in
a closed humid
area, the thickness
should be
increased.
9.5×0.8
120/140/160
15.9×1.0
Installation Manual
Installation instructions (Make sure you
hand over to the user)
Brass nut
For use in the installation of
connecting pipe (the quantity is one for
models with a process pipe)
Ring clamp
For use in the installation of connecting
pipes
Insulation piping
For insulation of piping connections
NAME
SHAPE
User Manual
Operating instructions (Make sure you
hand over to the user)
Remote controller
Flexible hose tube
Soundproof / insulation sheath
Out-let pipe sheath
Tightening band
Bolt M6
Nut
Washer
Sponge (250*250*10)
Sponge (60*100*5)
QUANTITY
1
1
1
1
2
2
4
2
1
5
1
8
8
1
1