Features of the UPS 

!

  True On-Line structure provides reliable, regulated, transient-free AC power. 

!

  High frequency designs to lower the size and weight. 

!

  Micro-Processor Control can increase the reliability. 

!

  High input power factor to meet the environmental concept for power saving. 

!

  Self-Diagnostic function can provide information for troubleshooting reference.  

!

  High capacity charger (10A) can rapidly charge the external battery bank.  

!

  Cold-start provides start-up power even during ac utility blackouts. 

!

  Sine wave regulated, low distortion inverter output. 

!

  Load and Battery capacity indicators. 

!

 Spike 

depression. 

!

 Computer 

interface 

card(RS-232). 

!

  Attractive office styling, easily accessible front panel controls. 

1.3 

Unpacking and Inspection 

Unpack all items and save the packing materials in case you ever need to move the system. Inspect the contents of 
the shipping carton as you unpack. If any of the following items are damaged or missing, contact your dealer 
immediately. 
 

!

 The 

UPS 

!

 This 

user’s 

guide 

!

  Two output power cord  

!

  One input power cord  

!

  One external battery wire (Long back-up time model only) 

 
For the UPS with battery inside, a small plastic plate is inserted to the power switch to  

prevent 

it 

from 

being 

accidentally switched on during shipment. 
 

 

CAUTION- Do not remove the power switch security plate until the UPS has been properly inspected and 
installed 

1.4 The 

Front 

Panel 

!

  (A) LINE: This green LED is on when the ac utility is normal, it is off when 

in battery mode. 

!

  (B) BYPASS: This yellow LED is on when the UPS is providing power 

directly from the incoming ac utility through the bypass line. 

!

  (C) INV: This green LED is on when the UPS power is from its inverter to 

the load. 

!

  (D) ALARM: This red LED is on when the UPS power is in a fault 

condition. In the meantime, the alarm beeps continuously. 

!

  (E) CAPACITY: This green LED bar indicates the load size in main mode 

or the  battery capacity in battery mode. In addition, it also indicates the 
fault status when the ALARM red LED is on. 

!

  (F) FULL LOAD: This yellow LED is on when the UPS is in full load 

condition; please unplug the least critical equipment, such as a printer 
etc. 

!

  (G) OVERLOAD: This red LED is on when the UPS is in over load condition. Unplug some equipment immediately 

until this LED is off. Otherwise the UPS will transfer to bypass mode after 20 seconds. 

CAUTION- Ensure this LED is off within 20 seconds in battery mode. Otherwise the UPS will be turned off 
because of no ac power in bypass.

 

!

  (H) MAIN SWITCH: Turn on the UPS by depressing this switch into “ | “ position and turn off the UPS by 

depressing this switch into “   ” position. 

18 

1.5 

Rear Panel of OMEGA 1000 

!

  (A)Power input socket 

: This socket is for the power cable of the 

UPS connected to the ac utility. 

!

  (B)Fuse holder: Contain the fuse of the UPS to protect the over current 

from the incoming ac utility. 

!

  (C)Power output sockets: This sockets are for the power cables of the 

devices connected to the UPS. 

!

  (D)Cooling fan: This fan is to prevent the UPS to overheat. 

!

  (E)Battery socket: This socket is for the external battery cable of the 

battery bank connected to the UPS. 

!

  (F)Interface socket: This socket combines contact closure signals and 

RS232 signals on one DB9 connector,  

1.6 

Rear Panel of OMEGA 2000 

!

  (A)Power input socket 

: (for 230VAC Model)This socket is for the 

power cable of the UPS connected to the ac utility Power input cable: (for 
115VAC Model)The power cable of the UPS connected to the ac utility. 

!

  (B)Fuse holder:  Contains the fuse of the UPS to protect the over current 

from the incoming ac utility 

!

  (C)Power output sockets: This sockets are for the power cables of the 

devices connected to the UPS. 

!

  (D)Cooling fan: This fan is to prevent the UPS to overheat. 

!

  (E)Battery socket: This socket is for the external battery cable of the 

battery bank connected to the UPS. 

!

  (F)Interface socket: This socket combines contact closure signals and 

RS232 signals on one DB9 connector. 

1.7 

Rear Panel of OMEGA 3000 

!

  (A)Power input socket 

: This socket is for the power cable of the 

UPS connected to the ac utility. 

!

  (B)Circuit breaker: Circuit breaker of the UPS to protect the over current 

from the incoming ac utility. 

!

  (C)Power output sockets: This sockets are for the power cables of the 

devices connected to the UPS. 

!

  (D)Cooling fan: This fan is to prevent the UPS to overheat. 

!

  (E)Battery socket: This socket is for the external battery cable of the 

battery bank connected to the UPS. 

!

  (F)Interface socket: This socket combines contact closure signals and 

RS232 signals on one DB9 connector 

 
 

1.8 

RS232 pin assignment and description 

 

PIN# Description 

I/O 

PIN 1 

RS232 DTR, must keep in high state 

Input 

PIN 2 

Line fail, normally open, active close 

Output 

PIN 3 

N.C. 

PIN 4 

Common for pin 2,5 

PIN 5 

Battery low, normally open, active close 

Output 

PIN 6 

Two purposes on this pin 

 

Input 

 

(1) Remote shut down, keep this pin high 

 

(+5~+12V) for 3 sec will turn off the UPS 

 

(2) RS232 Receiver Rx 

PIN 7 

Ground for pin 6,9 

PIN 8 

N.C. 

PIN 9 

RS232 Transmitter Tx Output 

Summary of Contents for Executive 3000

Page 1: ...sque de choc électrique Ne touchez pas aux bornes non isolées des batteries Déclaration FCC Cet appareil répond à la norme FCC article 15 et remplit ces deux conditions essentielles 1 Cet appareil ne doit pas provoquer d interférences dangereuses Et 2 Cet appareil doit pouvoir accepter tout type d interférence y compris des interférences pouvant créer des malfonctions Note Cet équipement à la suit...

Page 2: ...x de charge maximal Déconnectez immédiatement les appareils jusqu à ce qu elle s éteigne Dans le cas contraire l onduleur passera en mode BYPASS automatiquement au bout de 20 secondes ATTENTION Assurez vous que la LED s éteint avant les 20 secondes écoulées en mode batterie sinon l onduleur passé en mode bypass et ne détectant aucune source de courant s éteindra de lui même H MARCHE ARRET Pour all...

Page 3: ...t les conditions nécessaires pour s assurer de son bon fonctionnement et de son entretien 2 1 Mode normal Tant que le courant du secteur ne présente aucune anomalie de coupure l onduleur reste en mode normal il recharge ses batteries son panneau des LEDS s affiche comme indiqué dans la figure 2 1 2 2 Mode batteries Dès qu une anomalie se produit l onduleur passe en mode batteries les batteries se ...

Page 4: ... Continu Eteinte Toutes les 4 secondes Toutes les 15 secondes Chaque seconde 2 fois par seconde Variable suivant le type d alarme Affichage des LEDs LINE BYPASS INV ALARME SUR CHARGE ALARME SONORE Mode normal N A Mode normal N A Passe de bypass au mode convertisseur N A Mode batteries Vérifiez le secteur ou le fusible de l onduleur Fin d autonomie après 30 minutes N A Batterie basse N A Charge max...

Page 5: ...La función del UPS es proporcionar energía o alimentación a las computadoras o equipos electrónicos cuando ocurra una falla en el AC comercial Además este UPS protege los equipos contra cualquier irregularidad que se pueda presentar en la línea AC como lo son apagones subidas y caídas de voltaje e interferencia electromagnética y de radio frecuencia Permite la operación continua soportando la mayo...

Page 6: ...IN 7 Tierra para pin 6 9 PIN 8 N C PIN 9 RS232 Transmisión Tx salida 12 1 9 Selección del sitio Este UPS puede mantenerse de pie y esta diseñado para ser instalado en un ambiente controlado Asegúrese de que el aire fluya a través de las rejillas del UPS y que las mismas no estén obstruidas de lo contrario el UPS se puede recalentar Antes de cargar la batería del UPS seleccione un buen sitio para l...

Page 7: ...es considerablemente menor a la capacidad del UPS esta prueba puede durar varias horas 2 El tiempo de respaldo varía de acuerdo a la cantidad de uso al que estén sometidas las cargas Por ejemplo utilizar la unidad de disco consume más energía que correr programas del disco duro de la computadora 14 2 5 Apagando las cargas y el UPS Siga los siguientes pasos para apagar el UPS 1 Apague las cargas co...

Page 8: ...e top of batteries 5 Disconnect charging source prior to connecting or disconnecting battery terminals CAUTION Servicing of Battery Bank Connection should be performed by service personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries No User Serviceable Parts CAUTION Risk of electric shock Do not remove cover No user serviceable parts insi...

Page 9: ...seconds in battery mode Otherwise the UPS will be turned off because of no ac power in bypass H MAIN SWITCH Turn on the UPS by depressing this switch into position and turn off the UPS by depressing this switch into position 18 1 5 Rear Panel of OMEGA 1000 A Power input socket This socket is for the power cable of the UPS connected to the ac utility B Fuse holder Contain the fuse of the UPS to pro...

Page 10: ...ting modes of the UPS main mode and the battery mode It also describes how to operate maintain and store the UPS 2 1 Main Mode The main mode is one of the two operating modes of the UPS The UPS operates on this mode when the ac utility is normal During this mode the battery of the UPS charges Please refer to Fig 2 1 for the display on the UPS in this mode 2 2 Battery Mode The battery mode is the o...

Page 11: ...s Every second 2 times every second Depends on the Alarm condition LEDs Display LINE BYPASS INV ALARM OVER LOAD Buzzer Main mode operating N A Main mode operating N A Transferring from Bypass to Inverter N A Battery mode operating Check the ac utility or the fuse on the rear panel Battery discharges over 30 minutes N A Battery low warning N A Full load condition Unplug the least critical equipment...

Page 12: ...23 www unitek europe com ...

Reviews: