Chapter  3  20 Point Linearization

 (-LIN option)

3.1  20 Point Linearization Operation 

(-LIN option)

A 20 point linearization table is used to construct a curve describing the relationship of K-Factor and input 

frequency.  The measured input frequency is used to access the table.  A linear interpolation of adjacent 

point pairs is used to arrive at the K-Factor at that input frequency.  The fl ow rate and total are then com-

puted based upon the K-Factor for that measurement sample. 

NOTE:

   For best performance and resolution choose as many decimal places as possible in the K-

Factor.

 

   Example: Enter a K-Factor of 1 as 1.000.

Chapter  4  Programming

4.1 Explanation of Display Prompts

Save Total

: (Save Total) Press the 

E

 key while the unit is running to save the total value.  The display will show 

"

save total

" for a few seconds. This is a very useful "scratch pad" to save and restore total when replacing 

the battery(ies)

ent Code

: (enter code) This prompt will only appear if the panel lock is ON.  Press the 

↑ 

key to increment each digit.  

Press the 

 key to step to the next digit to the left.  Press the 

E

 key to enter the 5 digit code.  If the entered 

code is correct, the display will advance to the next menu prompt (CLr tot).  If incorrect, the display will return 
to the run mode.

Clr tot

: (clear total) Clears (resets) the totalizer.  Press the 

E

 key to clear the total and return to the run mode. Press 

the 

M

 key to skip and advance to the next menu selection.

fdeC

: (factor decimal) Sets the decimal location for the factor.  This location is restricted to 3 places (99.999). The use 

of this decimal automatically limits the number of decimal locations allowable in the rate and total to acceptable 
ranges.  Press the 

 key to move the decimal.  Press the 

E

 key to select the displayed decimal location.

NOTE:

 

For best performance and resolution choose as many decimal places as possible in the K-Factor.

 

 

Example: Enter a K-Factor of 1 as 1.000.

faC lInear

/

20poInt

: (factor type) This prompt will only appear if the unit is ordered with the 20 point linearization op-

tion.  The 

20 poInt

 linearization selection is recommended for fl ow meters whose K-factors change with different 

fl ow rates.  This selection allows users to enter up to 20 different frequencies with 20 corresponding K-factors for 
different fl ow rates.  The 

lInear 

setting is used for fl ow meters whose output is linear over its' entire operating 

fl ow range.  Press the 

↑ 

key to step to the desired choice.  Press the 

E

 key to enter the displayed factor type. 

No 

/

 yes  set Pnts

//

: (set 20 point?) This prompt allows the user to skip the 20 point setup routine.  Select 

yes  

for 

initial setup or to change the present 20 point values.  Select 

No 

to skip and keep the existing values.

faC 

: (factor) This prompt appears on all units with linear inputs. The Factor is the number of pulses per unit volume 
for the fl ow sensor. The pulses/unit volume is implied by the totalizer descriptor when a descriptor is used. The 
implied units for the Factor are then as follows:

 

GAL 

pulses/gallon

 

LIT 

pulses/liter

 

FT3 

pulses/ft3

 

M3 

pulses/M3

 

Factors from 0.0001 to 99999999 may be used.  A "0" value for the factor is not allowed and the unit will default 
to "1" in LSD if a "0" entry is attempted .  The factor is displayed on the subsidiary (lower) display.  Press the 

↑ 

key to increment each digit.  Press the 

 key to step to the next digit to the left.  Press the 

E

 key to enter the 

displayed factor.

Summary of Contents for DPF500 Series

Page 1: ...omega com e mail info omega com For latest product manuals omegamanual info DPF500 Series Ratemeter Totalizer Shop online at User sGuide...

Page 2: ...78280 Guyancourt France TEL 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056...

Page 3: ...nsions 3 2 4 Wiring 4 2 5 Typical Applications Wiring Diagrams 4 Chapter 3 20 Point Linearization Operation 3 1 20 Point Linearization LIN option 5 Chapter 4 Programming 4 1 Explanation of Display Pro...

Page 4: ...ii THIS PAGE INTENTIONALLY BLANK...

Page 5: ...Optically Isolated Displays Rate Total Simultaneously 5 Digit Rate Display 8 Digit Totalizer Display 4 20mA Analog Output MA option Powered From Internal Battery or 4 20 mA Output Loop MA option 20 P...

Page 6: ...its end of life A descriptor BAT illuminates when the battery voltage falls below this predetermined value The low bat tery detector operates correctly with all power options The battery or batteries...

Page 7: ...emove cover and 4 panel screws Terminals are on bottom side of PC board Panel Screws 4 92 125 TOP VIEW PANEL INSTALLED 4 63 117 3 4 NPT 2 HLS 5 00 127 5 16 4 25 108 5 25 133 E M 5 00 127 To access ter...

Page 8: ...owmeter with DC Pulse Output Strip Char t Recorder 24 VDC Power Supply ISOLATED INPUT 4 20mA LOOP POWERED NOTE Separate power supplies are recommended to isolate output from input If isolation is not...

Page 9: ...the number of decimal locations allowable in the rate and total to acceptable ranges Press the key to move the decimal Press the E key to select the displayed decimal location NOTE For best performan...

Page 10: ...n GAL BBL MCF M3 blank Press the key to select the descrip tor Press the E key to enter the selected descriptor r sCale ratemeter scaling Sets the rate readout Choose rate per hour Hrs minutes nnIn or...

Page 11: ...divider may be needed so that the pulse output does not exceed the maximum rate of the pulse output If the pulse output pulses too quickly a ashing display will result Pressing the M key will result...

Page 12: ...y to step the factor decimal to the desired location Press the E key to enter the displayed decimal location Press the M key to skip and keep the existing location NOTE For best performance and resolu...

Page 13: ...s the value This will only display on units with Analog Output key to advance to the next digit Press the E key to enter the displayed value Press the M key to skip and keep the existing value Press t...

Page 14: ...ommon To reset the unit from the front panel the following key sequence is required Press M CLr tot will be displayed if the panel lock is on the display will prompt ent code Enter the proper code to...

Page 15: ...gital milliamp meter DMM in series with the analog output and simulating a full scale or over range ow rate If the output is out of calibration perform the following Remove power and or disconnect bat...

Page 16: ...r BATTERY POWERED Supplied with 1 or 2 C size Lithium battery pack EXTERNAL POWER INPUT Voltage 8 5 to 30 VDC Current Less than 5 mA Supplied with 1 C size lithium battery Protection Reverse Polarity...

Page 17: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 18: ...ty Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...

Reviews: