8

4.2 Programming Flowchart

RATE

RA

RA

TOTAL

CLR ToT

FDEC

12345678

M

RUN MODE

CLEAR TOTAL

OT

OT

FACTOR
DECIMAL

FAC

100

FACTOR

0000

ent Code

ENTER CODE

If panel
lock ON

If panel
lock OFF

If  code
correct

If  code
incorrect

FAC

20poInt

FACTOR
TYPE

20poInt

lInear

lInear

selected

E

M

E

E

M

E

M

E

M

20poInt

selected

Continue On

Next Page

Fr#

#####

FREQUENCY
for POINT #
(Fr0-Fr19)

FaC#

#####

FACTOR for
POINT #
(FAC0-FAC19)

If  Fr1-FR19 = 0

# = 19

E

M

E

M

YES

   SET pnts

E

M

YES

No

SET

20PT

YES

selected

No

selected

Press the 

key to enter the programming menu.

The 

SET pnts

 prompt will only appear if 

20point 

is selected. This allows users 

to bypass the 20 point set up and keep the existing values.

Press the   key to choose YES or NO.
Press the 

key to enter the displayedselection.

Press the 

key to skip (same as selecting NO).

If the panel lock is on, you must enter the 4 digit lock code to gain access 

to the menu.

Press the   key to increment each individual digit of the code.
Press the 

 key to advance to the next digit.

Press the 

key to enter the displayed code.

If the code is correct, display advances to "

clr tot

", if not, display returns 

to run mode

Press the 

key to clear the totalizer and return to the programming menu.

Press the 

key to skip and go to next menu item.

Press the 

 key to step the factor decimal to the desired location.

Press the 

key to enter the displayed decimal location.

Press the 

M key

 to skip and keep the existing location

NOTE:

  For best performance and resolution choose as many decimal places as 

possible in the K-Factor.Example: Enter a K-Factor of 1 as 1.000.

Press the   key to choose factor type (

20point 

or 

linear

).

Press the 

key to enter the displayed factor type.

Press the 

key to skip and keep the existing factor type.

Press the   key to increment each individual digit of the factor for point #.
Press the 

 key to advance to the next digit.

Press the 

key to enter the displayed factor.

Press the 

key to skip and keep the existing factor.

If 0 is entered, the display will advance to the next prompt (tdec).

Press the   key to increment each individual digit of the frequency for point 

#.

Press the 

 key to advance to the next digit.

Press the 

key to enter the displayed frequency.

Press the 

key to skip and keep the existing frequency.

If 0 is entered, the display will advance to the next prompt (tdec).

NOTE:

  Frequency/factor  point  pairs  must  be  entered  in  ascending  order  of  fre-

quency

The 

FAC

 prompt will only appear if 

linear 

is selected or if the unit was ordered 

without the 20 point linearization option.

Press the   key to increment each individual digit of the factor.
Press the 

 key to advance to the next digit.

Press the 

key to enter the displayed factor.

Press the 

key to skip and keep the existing factor.

Summary of Contents for DPF500 Series

Page 1: ...omega com e mail info omega com For latest product manuals omegamanual info DPF500 Series Ratemeter Totalizer Shop online at User sGuide...

Page 2: ...78280 Guyancourt France TEL 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056...

Page 3: ...nsions 3 2 4 Wiring 4 2 5 Typical Applications Wiring Diagrams 4 Chapter 3 20 Point Linearization Operation 3 1 20 Point Linearization LIN option 5 Chapter 4 Programming 4 1 Explanation of Display Pro...

Page 4: ...ii THIS PAGE INTENTIONALLY BLANK...

Page 5: ...Optically Isolated Displays Rate Total Simultaneously 5 Digit Rate Display 8 Digit Totalizer Display 4 20mA Analog Output MA option Powered From Internal Battery or 4 20 mA Output Loop MA option 20 P...

Page 6: ...its end of life A descriptor BAT illuminates when the battery voltage falls below this predetermined value The low bat tery detector operates correctly with all power options The battery or batteries...

Page 7: ...emove cover and 4 panel screws Terminals are on bottom side of PC board Panel Screws 4 92 125 TOP VIEW PANEL INSTALLED 4 63 117 3 4 NPT 2 HLS 5 00 127 5 16 4 25 108 5 25 133 E M 5 00 127 To access ter...

Page 8: ...owmeter with DC Pulse Output Strip Char t Recorder 24 VDC Power Supply ISOLATED INPUT 4 20mA LOOP POWERED NOTE Separate power supplies are recommended to isolate output from input If isolation is not...

Page 9: ...the number of decimal locations allowable in the rate and total to acceptable ranges Press the key to move the decimal Press the E key to select the displayed decimal location NOTE For best performan...

Page 10: ...n GAL BBL MCF M3 blank Press the key to select the descrip tor Press the E key to enter the selected descriptor r sCale ratemeter scaling Sets the rate readout Choose rate per hour Hrs minutes nnIn or...

Page 11: ...divider may be needed so that the pulse output does not exceed the maximum rate of the pulse output If the pulse output pulses too quickly a ashing display will result Pressing the M key will result...

Page 12: ...y to step the factor decimal to the desired location Press the E key to enter the displayed decimal location Press the M key to skip and keep the existing location NOTE For best performance and resolu...

Page 13: ...s the value This will only display on units with Analog Output key to advance to the next digit Press the E key to enter the displayed value Press the M key to skip and keep the existing value Press t...

Page 14: ...ommon To reset the unit from the front panel the following key sequence is required Press M CLr tot will be displayed if the panel lock is on the display will prompt ent code Enter the proper code to...

Page 15: ...gital milliamp meter DMM in series with the analog output and simulating a full scale or over range ow rate If the output is out of calibration perform the following Remove power and or disconnect bat...

Page 16: ...r BATTERY POWERED Supplied with 1 or 2 C size Lithium battery pack EXTERNAL POWER INPUT Voltage 8 5 to 30 VDC Current Less than 5 mA Supplied with 1 C size lithium battery Protection Reverse Polarity...

Page 17: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 18: ...ty Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...

Reviews: