4.2 Programming Flowchart 

(continued)

Press the 

 key to step the totalizer decimal to the desired location.

Press the 

key to enter the displayed decimal location.

Press the 

key to skip and keep the existing location

Press the   key to step to the desired totalizer descriptor.

Press the 

key to enter the displayed descriptor.

Press the 

key to skip and keep the existing descriptor.

NOTE:

  When option "D" (rate per day) is ordered; selections are: 

 

GAL, BBL, MCF, M3, "blank"

Press the   key to step to the desired scale setting.

Press the 

key to enter the displayed scale setting.

Press the 

key to skip and keep the existing setting.

NOTE:

  When option "D" (rate per day) is ordered; selections are: 

 

min, sec, days

Press the 

 key to step the ratemeter decimal to the desired location.

Press the 

key to enter the displayed decimal location.

Press the 

key to skip and keep the existing location

Press the   key to increment each individual digit of the delay.

Press the 

 key to advance to the next digit.

Press the 

key to enter the displayed value.

Press the 

key to skip and keep the existing value.

Press the   key to increment each individual digit of the out low setting (4mA 

value). 

This will only display on units with Analog Output.

Press the 

 key to advance to the next digit.

Press the 

key to enter the displayed value.

Press the 

key to skip and keep the existing value.

Press the   key to increment each individual digit of the out high setting (20mA 

value). 

This will only display on units with Analog Output. 

Press the 

 key to advance to the next digit.

Press the 

key to enter the displayed value.

Press the 

key to skip and keep the existing value.

Press the   key to step to the desired pulse scale divider for the pulse 

output.

Press the 

key to enter the displayed pulse scale divider.

Press the 

key to skip and keep the existing pulse scale value.

Press the   key to step to the desired pulse width for the pulse output.

Press the 

key to enter the displayed pulse width.

Press the 

key to skip and keep the existing pulse width.

This will not display if Pulse Out is turned OFF.

Press the   key to increment each individual digit of the "nor" factor.

Press the 

key to enter the displayed value.

Press the 

key to skip and keep the existing value.

TDEC

12345678

ToT DESC

SEC

r  SCALE

TOT AL  DECIMAL

TOT AL
DESCRIPT OR

SCALE
(ratemeter)

SEC

NNIN

HRS

(

Days

)

GAL

LIT

FT3

M3

"blank"

(BBL, MCF)

1234

R DECLoC

RA TE

DECIMAL
LOCA TION

E

M

E

M

E

M

E

M

0.1

delay

0000

oUT Lo

99999

oUT HI

D  1

Pul scale

DELA Y

OUT LOW
(4mA)

OUT HIGH
(20mA)

PULSE
SCALER
(divider)

D  1

D  1

D 10

D 10

D100

D100

oFF

oFF

0.1

to

 99.9

to

to

E

M

E

M

E

M

E

M

       .5

       .5

p uuidth

E

M

.5
.25
.125
.0625

PULSE
WIDTH
(seconds)

1

nor

NORMALIZATION

NORMALIZA

NORMALIZA

E

M

Continued From Previous Page

RUN MODE

0000

loc code

LOCK
CODE

E

M

yes

loC UnIt

TURN LOCK
ON or OFF

yes

no

E

M

Press the   key to step to the desired lock setting.

Press the 

key to enter the displayed lock setting.

Press the 

key to skip and keep the existing setting.

Press the   key to increment each individual digit of the lock code.

Press the 

 key to advance to the next digit.

Press the 

key to enter the displayed value.

Press the 

key to skip and keep the existing value.

Summary of Contents for DPF500 Series

Page 1: ...omega com e mail info omega com For latest product manuals omegamanual info DPF500 Series Ratemeter Totalizer Shop online at User sGuide...

Page 2: ...78280 Guyancourt France TEL 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056...

Page 3: ...nsions 3 2 4 Wiring 4 2 5 Typical Applications Wiring Diagrams 4 Chapter 3 20 Point Linearization Operation 3 1 20 Point Linearization LIN option 5 Chapter 4 Programming 4 1 Explanation of Display Pro...

Page 4: ...ii THIS PAGE INTENTIONALLY BLANK...

Page 5: ...Optically Isolated Displays Rate Total Simultaneously 5 Digit Rate Display 8 Digit Totalizer Display 4 20mA Analog Output MA option Powered From Internal Battery or 4 20 mA Output Loop MA option 20 P...

Page 6: ...its end of life A descriptor BAT illuminates when the battery voltage falls below this predetermined value The low bat tery detector operates correctly with all power options The battery or batteries...

Page 7: ...emove cover and 4 panel screws Terminals are on bottom side of PC board Panel Screws 4 92 125 TOP VIEW PANEL INSTALLED 4 63 117 3 4 NPT 2 HLS 5 00 127 5 16 4 25 108 5 25 133 E M 5 00 127 To access ter...

Page 8: ...owmeter with DC Pulse Output Strip Char t Recorder 24 VDC Power Supply ISOLATED INPUT 4 20mA LOOP POWERED NOTE Separate power supplies are recommended to isolate output from input If isolation is not...

Page 9: ...the number of decimal locations allowable in the rate and total to acceptable ranges Press the key to move the decimal Press the E key to select the displayed decimal location NOTE For best performan...

Page 10: ...n GAL BBL MCF M3 blank Press the key to select the descrip tor Press the E key to enter the selected descriptor r sCale ratemeter scaling Sets the rate readout Choose rate per hour Hrs minutes nnIn or...

Page 11: ...divider may be needed so that the pulse output does not exceed the maximum rate of the pulse output If the pulse output pulses too quickly a ashing display will result Pressing the M key will result...

Page 12: ...y to step the factor decimal to the desired location Press the E key to enter the displayed decimal location Press the M key to skip and keep the existing location NOTE For best performance and resolu...

Page 13: ...s the value This will only display on units with Analog Output key to advance to the next digit Press the E key to enter the displayed value Press the M key to skip and keep the existing value Press t...

Page 14: ...ommon To reset the unit from the front panel the following key sequence is required Press M CLr tot will be displayed if the panel lock is on the display will prompt ent code Enter the proper code to...

Page 15: ...gital milliamp meter DMM in series with the analog output and simulating a full scale or over range ow rate If the output is out of calibration perform the following Remove power and or disconnect bat...

Page 16: ...r BATTERY POWERED Supplied with 1 or 2 C size Lithium battery pack EXTERNAL POWER INPUT Voltage 8 5 to 30 VDC Current Less than 5 mA Supplied with 1 C size lithium battery Protection Reverse Polarity...

Page 17: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 18: ...ty Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...

Reviews: