PLATINUM
TM
Series User’s Guide
57
Specifications
External Fuse
Required
Time-Delay, UL 248-14 listed:
•
100 mA/250 V
•
400 mA/250 V (Low-Voltage Option)
Time-Lag, IEC 127-3 recognized:
•
100 mA/250 V
•
400 mA/250 V (Low-Voltage Option)
Line Voltage/Power
•
90–240 Vac +/-10%, 50-400 Hz
•
110–375 Vdc, equivalent voltage
•
4 W: power for 8Pt, 16Pt, 32Pt Models
•
5 W: power for 8DPt, 16DPt Models
Low-Voltage/Power
Option
External power source must meet Safety Agency Approvals. Units can be
powered safely with 24 Vac power, but no certification for CE/UL is claimed.
•
12–36 Vdc: 3 W power for 8Pt, 16Pt, 32Pt
•
20–36 Vdc: 4 W power for 8DPt, 16DPt
Protection
•
NEMA-4x/Type 4x/IP65 front bezel: 32Pt, 16Pt, 16DPt
•
NEMA-1/Type 1 front bezel: 8Pt, 8DPt
Weight
•
8Pt Series: 295 g (0.65 lb)
•
16Pt Series: 159 g (0.35 lb)
•
32Pt Series: 127 g (0.28 lb)
1
No CE compliance above 60 Hz
Omega Engineering | www.omega.com