EnForcer™ SCR
Service Manual
I.B. 1561
17
chosen above.
Do not adjust unless order acknowledgement specifies a change.
D e l t a
V o l t a g e -
d v / d t
Delta Voltage- dv/dt
The change in battery voltage over time limit that the charger monitors, in
order to determine charge completion. Units are in mV/cell. High values
correspond to a shorter charge cycle.
Do not adjust unless order acknowledgement specifies a change.
0-50
10
T i m e a f t e r
G a s s i n g
Time after Gassing Voltage
Time limit for time-voltage and
Both
termination modes (see above).
Do not adjust unless order acknowledgement specifies a change.
0:00 – 10:00
5:00
P r o p o r t i o n a l
F a c t o r
Proportional Factor
For proportional termination mode, this parameter specifies the percentage
of start rate time to continue charging after reaching gassing voltage.
Do not adjust unless order acknowledgement specifies a change.
0 – 100
40
F i n i s h
C u r r e n t
Finish Current
Setting for finish rate current in amps. This is automatically set to 4.5% of
battery amp-hours when either battery amp-hours or charger amp-hours is
set. If Sealed profile is chosen (VRLA), then this value is set to 2.5% of
battery amp-hours. The maximum setting is 16% of charger nameplate
amp-hours.
Do not adjust unless order acknowledgement specifies a change.
3 – 200
38
S t a r t
C u r r e n t
Start Current
Setting for start rate current in amps. This is automatically set to 16% of
battery amp-hours when either battery amp-hours or charger amp-hours is
set. The maximum setting is 16% of charger nameplate amp-hours.
Do not adjust unless order acknowledgement specifies a change.
3 – 400
136
C h a r g e
P r o f i l e
Charge Profile
1 = IEI (flooded)
2 = IEIE (sealed- VRLA)
3= AGV ( Auto guided vehicle)
4= I (VVR) 5 = IE ( Floating mode )
6= Opportunity
This should be set to match the type of battery that the charger will be
charging.
1 – 6
1
S e a l e d
F i n i s h V o l t s
Sealed Finish Volts
For sealed (VRLA) charge profiles, the final voltage, in volts per cell.
Do not adjust unless order acknowledgement specifies a change.
1.000 –
3.000
2.530
S e a l e d
F i n i s h T i m e
Sealed Finish Time
For sealed (VRLA) charge profiles, the maximum time to stay in the final
voltage stage.
Do not adjust unless order acknowledgement specifies a change.
0:00 – 12:00
2:00
E q u a l i z e o n
D a y 1
Equalize on Day 1
Equalize on a particular day of the week after charge cycle completes. Set
from Sunday – Saturday or OFF. Used in conjunction with the real-time-
clock. Will disable Equalize by Count in USER Parameters when ON.
Do not adjust unless order acknowledgement specifies a change.
Sunday-
Saturday or
OFF
OFF
E q u a l i z e o n
D a y 2
Equalize on Day 2
Second day equalize setting similar to above. Equalize on a particular day
of the week after charge cycle completes. Set from Sunday – Saturday or
OFF. Used in conjunction with the real-time-clock. Will disable Equalize by
Count in User Parameters when ON.
Do not adjust unless order acknowledgement specifies a change.
Sunday-
Saturday or
OFF
OFF
B l o c k O u t
t i m e S t a r t
Block out Start Time
Start time for charger block out period. Setting 00:00 is OFF.
Do not adjust unless order acknowledgement specifies a change.
00:00(OFF)
00:01-23:59
00:00
B l o c k O u t
t i m e S t o p
Block out Stop Time
Stop time for charger block out period. Setting 00:00 is OFF.
Do not adjust unless order acknowledgement specifies a change.
00:00(OFF)
00:01-23:59
00:00
E n a b l e
F o r c e d S t a r t
Enable Forced Start
Enable/Disable the charger control forced start function.
Do not adjust unless order acknowledgement specifies a change.
0(OFF)
1(ON)
1
Summary of Contents for Millennium-E
Page 1: ...Owner s Manual ...
Page 8: ...The Ultimate Ice Resurfacer ...
Page 96: ...The Ultimate Ice Resurfacer 88 8 9 10 11 12 13 14 18 15 16 17 ...
Page 100: ...The Ultimate Ice Resurfacer 92 ...
Page 101: ...The Ultimate Ice Resurfacer 93 ...
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 115: ...I B 1561 Rev B Model ES3 EnForcer SCR Battery Charger Service Manual ...
Page 148: ...EnForcer SCR Service Manual I B 1561 34 ES3 REPLACEMENT PARTS SCHEMATICS ...
Page 156: ...EnForcer SCR Service Manual I B 1561 42 SCHEMATIC DIAGRAM ES3 ...
Page 157: ...EnForcer SCR Service Manual I B 1561 43 ES3 ASSEMBLY DRAWING ...
Page 159: ...EnForcer SCR Service Manual I B 1561 45 INTERIOR VIEWS ...
Page 160: ...EnForcer SCR Service Manual I B 1561 46 SINGLE EXTRUSION HEAT SINK ASSEMBLY ...
Page 162: ...EnForcer SCR Service Manual I B 1561 48 THREE EXTRUSION HEAT SINK ASSEMBLY ...
Page 164: ...EnForcer SCR Service Manual I B 1561 50 SUB ASSEMBLY PANEL ASSEMBLY ...
Page 167: ...EnForcer SCR Service Manual I B 1561 53 DOOR ASSEMBLY ...
Page 168: ...EnForcer SCR Service Manual I B 1561 54 PARALLEL CABLES OPTIONAL ...
Page 169: ...EnForcer SCR Service Manual I B 1561 55 DISCONNECT SWITCH OPTIONAL ...
Page 170: ...EnForcer SCR Service Manual I B 1561 56 CABINET ASSEMBLY ...
Page 171: ...EnForcer SCR Service Manual I B 1561 57 CABINET ASSEMBLY EXPLODED VIEW ...
Page 174: ...EnForcer SCR Service Manual I B 1561 60 SCHEMATIC DIAGRAM ...
Page 175: ...EnForcer SCR Service Manual I B 1561 62 ES3 LARGE CABINET ASSEMBLY DRAWINGS ...
Page 176: ...EnForcer SCR Service Manual I B 1561 63 CHARGER INTERIOR VIEW ...
Page 177: ...EnForcer SCR Service Manual I B 1561 64 TRANSFORMER CONNECTIONS ...
Page 178: ...EnForcer SCR Service Manual I B 1561 65 HEAT SINK ASSEMBLY ...
Page 179: ...EnForcer SCR Service Manual I B 1561 66 HEAT SINK ASSEMBLY CON T ...
Page 180: ...EnForcer SCR Service Manual I B 1561 67 SUB ASSEMBLY PANELS ...
Page 181: ...EnForcer SCR Service Manual I B 1561 68 CABINET ASSEMBLY ...
Page 182: ...EnForcer SCR Service Manual I B 1561 69 CABINET ASSEMBLY CON T ...
Page 183: ......
Page 184: ......
Page 185: ......
Page 186: ......
Page 187: ......
Page 188: ......
Page 189: ......
Page 190: ......
Page 191: ......
Page 192: ......
Page 193: ......
Page 194: ......
Page 195: ......
Page 196: ......
Page 197: ......