4265 Jointer
OLIVERMACHINERY.NET
27
|
Page
Digital Readout (DRO
)
This jointer is equipped with a Wixey DRO with
0.005”/0.05mm resolution.
On/Off Button
To turn on/off this DRO. It is also for calibration
in ABS (absolute) mode.
MM/IN Button
Toggles between inch and mm as measurement
unit. When the reading gets close to a multiple
of 1/32, its fractional value will show on the
screen.
ABS/INC Button
Toggles between
Absolute
and
Incremental
mode.
Absolute mode shows total depth of cut. Once
calibrated, settings will be memorized unless the
battery is exhausted, OR if user recalibrates the
DRO.
Incremental mode shows distance infeed table
travelled since the last reset. The readings can be
reset by leaving incremental mode.
DRO Calibration
1.
Disconnect jointer from power source!!
2.
Set infeed table depth of cut to zero.
3.
Turn on DRO and switch to ABS mode.
4.
Hold ON/OFF button for 3-5 seconds until
“ABS” is blinking on display. As the button is
released, readings will be reset to zero.
5.
Press ON/OFF button again to leave
calibration mode.
Summary of Contents for 4265
Page 2: ......
Page 10: ...10 Page Oliver Machinery 4265 Jointer Identification...
Page 11: ...4265 Jointer OLIVERMACHINERY NET 11 Page...
Page 51: ...4265 Jointer OLIVERMACHINERY NET 51 Page Wiring Diagram For Stock 4265 101 4S 230V 1Ph...
Page 52: ...52 Page Oliver Machinery 4265 Jointer For Stock 4265 102 4S 230 460V 3Ph...
Page 53: ...4265 Jointer OLIVERMACHINERY NET 53 Page Parts List Fence Assembly...
Page 54: ...54 Page Oliver Machinery 4265 Jointer Table and Cutterhead Assembly...
Page 55: ...4265 Jointer OLIVERMACHINERY NET 55 Page Base Assembly...
Page 56: ...56 Page Oliver Machinery 4265 Jointer Motor and Cabinet...
Page 66: ...66 Page Oliver Machinery 4265 Jointer Maintenance Record Date Task Operator...
Page 67: ...4265 Jointer OLIVERMACHINERY NET 67 Page Notes...